-
- Tarek Hijal, Nathalie Fournier-Bidoz, Pablo Castro-Pena, Youlia M Kirova, Sophia Zefkili, Marc A Bollet, Rémi Dendale, François Campana, and Alain Fourquet.
- Department of Radiation Oncology, Institut Curie, Paris, France. tarekhijal@hotmail.com
- Radiother Oncol. 2010 Mar 1; 94 (3): 300-6.
Background And PurposeTo evaluate the dosimetry of helical tomotherapy (HT) and three-dimensional conformal radiotherapy (3D-CRT) in breast cancer patients undergoing whole breast radiation with simultaneous integrated boost (SIB) of the tumor bed.Material And MethodsThirteen patients with breast cancer treated by lumpectomy and requiring whole breast radiotherapy with tumor bed boost were planned using both HT and 3D-CRT using the field-in-field technique. The whole breast and tumor bed were prescribed 50.68 Gy and 64.4 Gy, respectively, in 28 fractions. Dosimetries for both techniques were compared.ResultsCoverage of the whole breast was adequate with both techniques (V(95%)=96.22% vs. 96.25%, with HT and 3D-CRT, respectively; p=0.64). Adequate tumor bed coverage was also achieved, although it was significantly lower with HT (V(95%)=97.18% vs. 99.72%; p<0.001). Overdose of the breast volume outside the tumor bed was significantly lower with HT (V(54.23 Gy)=12.47% vs. 30.83%; p<0.001). Ipsilateral lung V(20 Gy) (6.34% vs. 10.17%; p<0.001), V(5 Gy) (16.54% vs. 18.53%; p<0.05) and mean dose (4.05 Gy vs. 6.36 Gy; p<0.001) were significantly lower with HT. In patients with left-sided tumors, heart V(30 Gy) (0.03% vs. 1.14%; p<0.05) and mean dose (1.35 Gy vs. 2.22 Gy; p<0.01) were significantly lower with HT, but not V(5 Gy). Contralateral breast V(5 Gy) (0.27% vs. 0.00%; p<0.01) and maximum dose were significantly increased with HT.ConclusionsIn breast cancer treated with SIB, both HT and 3D-CRT provided adequate target volume coverage and low heart doses. Tumor bed coverage was slightly lower with HT, but HT avoided unnecessary breast overdosage while improving ipsilateral lung dosimetry.(c) 2010 Elsevier Ireland Ltd. All rights reserved.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.