J Magn Reson Imaging · Mar 1997
Comparative Study Clinical Trial Controlled Clinical TrialPhased array breath-hold versus non-breath-hold MR imaging of focal liver lesions: a prospective comparative study.
- Y Yamashita, H Yamamoto, T Namimoto, Y Abe, and M Takahashi.
- Department of Radiology, Kumamoto University School of Medicine, Japan.
- J Magn Reson Imaging. 1997 Mar 1; 7 (2): 292-7.
AbstractThis study was undertaken to determine whether phased array breath-hold T1- and T2-weighted sequences can replace non-breath-hold spin echo (SE) sequences in the imaging of focal liver lesions by comparing overall image quality, liver-lesion contrast, and artifact. Both breath-hold and non-breath-hold T1-weighted and T2-weighted imagings of focal liver lesions were prospectively compared in 120 patients with suspected focal liver lesions imaged at 1.5 T with use of a body phased array multicoil. Breath-hold images were acquired with T1-weighted fast low-angle shot (FLASH) and T2-weighted turbo spin echo (TSE) sequences, and non-breath-hold images were made with conventional T1- and T2-weighted SE sequences. Qualitative image analysis was done by three blinded readers, and quantitative analysis was done. The highest signal-to-noise ratios were obtained with breath-hold T1-weighted FLASH sequence. The signal-to-noise ratios of breath-hold T2-weighted TSE sequence were slightly inferior to those of non-breath-hold SE sequence. Both T1-weighted and T2-weighted breath-hold sequences had less image artifact. Overall image quality of breath-hold sequences was better than that of non-breath-hold sequences for both T1- and T2-weighted sequences (P < .01). The tissue contrast of T1-weighted FLASH sequence was superior to that of SE sequence (P < .01). On T2-weighted imaging, tissue contrast of solid lesions was better on conventional SE sequence than that on breath-hold TSE sequence (P < .01). Respiratory ghost artifact was less prominent on T1-weighted FLASH sequence, although this artifact was occasionally seen on breath-hold T2-weighted TSE sequence. In a state-of-art MR unit with use of a phased array multicoil, conventional T1-weighted can be replaced by breath-hold sequences. On T2-weighted imaging, because solid tumor-liver contrast on breath-hold TSE imaging is inferior to that on non-breath-hold SE image, breath-hold imaging may not replace conventional non-breath-hold T2-weighted SE sequence.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.