-
Comparative Study
Office hours pulsed brachytherapy boost in breast cancer.
- P Sminia, C J Schneider, G van Tienhoven, K Koedooder, L E Blank, and D González González.
- Department of Radiation Oncology, Academic Medical Center, University of Amsterdam, Meibergdreef 9, 1105 AZ, Amsterdam, The Netherlands.
- Radiother Oncol. 2001 Jun 1; 59 (3): 273-80.
Background And PurposeRadiobiological studies suggest equivalent biological effects between continuous low dose rate brachytherapy (CLDR) and pulsed brachytherapy (PB) when pulses are applied without interruption every hour. However, radiation protection and institute-specific demands requested the design of a practical PB protocol substituting the CLDR boost in breast cancer patients. An office hours scheme was designed, considering the CLDR dose rate, the overall treatment time, pulse frequency and tissue repair characteristics. Radiobiological details are presented as well as the logistics and technical feasibility of the scheme after treatment of the first 100 patients.Materials And MethodsBiologically effective doses (BEDs) were calculated according to the linear quadratic model for incomplete repair. Radiobiological parameters included an alpha/beta value of 3 Gy for normal tissue late effects and 10 Gy for early normal tissue or tumour effects. Tissue repair half-time ranged from 0.1 to 6 h. The reference CLDR dose rate of 0.80 Gy/h was obtained retrospectively from analysis of patients' data. The treatment procedure was evaluated with regard to variations in implant characteristics after treatment of 100 patients.ResultsA PB protocol was designed consisting of two treatment blocks separated by a night break. Dose delivery in PB was 20 Gy in two 10 Gy blocks and, for application of the 15 Gy boost, one 10 Gy block plus one 5 Gy block. The dose per pulse was 1.67 Gy, applied with a period time of approximately 1.5 h. An inter-patient variation of 30% (1 SD) was observed in the instantaneous source strength. Taking also the spread in implant size into account, the net variation in pulse duration amounted to 38%.ConclusionAn office hours PB boost regimen was designed for substitution of the CLDR boost in breast-conserving therapy on the basis of the BED. First treatment experience shows the office hour regimen to be convenient to the patients and no technical perturbations were encountered.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.