• Blood Coagul. Fibrinolysis · Jan 2013

    Clinical Trial

    Evaluation of the Q analyzer, a new cap-piercing fully automated coagulometer with clotting, chromogenic, and immunoturbidometric capability.

    • Steve Kitchen and Anita Woolley.
    • Department of Coagulation, Royal Hallamshire Hospital, Glossop Road, Sheffield, UK. steve.kitchen@sth.nhs.uk
    • Blood Coagul. Fibrinolysis. 2013 Jan 1; 24 (1): 28-34.

    AbstractThe Q analyzer is a recently launched fully automated photo-optical analyzer equipped with primary tube cap-piercing and capable of clotting, chromogenic, and immunoturbidometric tests. The purpose of the present study was to evaluate the performance characteristics of the Q analyzer with reagents from the instrument manufacturer. We assessed precision and throughput when performing coagulation screening tests, prothrombin time (PT)/international normalized ratio (INR), activated partial thromboplastin time (APTT), and fibrinogen assay by Clauss assay. We compared results with established reagent instrument combinations in widespread use. Precision of PT/INR and APTT was acceptable as indicated by total precision of around 3%. The time to first result was 3  min for an INR and 5  min for PT/APTT. The system produced 115 completed samples per hour when processing only INRs and 60 samples (120 results) per hour for PT/APTT combined. The sensitivity of the DG-APTT Synth/Q method to mild deficiency of factor VIII (FVIII), IX, and XI was excellent (as indicated by APTTs being prolonged above the upper limit of the reference range). The Q analyzer was associated with high precision, acceptable throughput, and good reliability. When used in combination with DG-PT reagent and manufacturer's instrument-specific international sensitivity index, the INRs obtained were accurate. The Q analyzer with DG-APTT Synth reagent demonstrated good sensitivity to isolated mild deficiency of FVIII, IX, and XI and had the advantage of relative insensitivity to mild FXII deficiency. Taken together, our data indicate that the Q hemostasis analyzer was suitable for routine use in combination with the reagents evaluated.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…