- Yang Liu, Ze Wang, Ruihua Liang, Zhengrong Liang, and Hongbing Lu.
- School of Biomedical Engineering, Fourth Military Medical University, Xi'an, China.
- Biomed Eng Online. 2019 Feb 4; 18 (1): 12.
BackgroundArterial spin labeling (ASL) provides a noninvasive way to measure cerebral blood flow (CBF). The CBF estimation from ASL is heavily contaminated by noise and the partial volume (PV) effect. The multiple measurements of perfusion signals in the ASL sequence are generally acquired and were averaged to suppress the noise. To correct the PV effect, several methods were proposed, but they were all performed directly on the averaged image, thereby ignoring the inherent perfusion information of mixed tissues that are embedded in multiple measurements. The aim of the present study is to correct the PV effect of ASL sequence using the inherent perfusion information in the multiple measurements.MethodsIn this study, we first proposed a statistical perfusion model of mixed tissues based on the distribution of multiple measurements. Based on the tissue mixture that was obtained from the high-resolution structural image, a structure-based expectation maximization (sEM) scheme was developed to estimate the perfusion contributions of different tissues in a mixed voxel from its multiple measurements. Finally, the performance of the proposed method was evaluated using both computer simulations and in vivo data.ResultsCompared to the widely used linear regression (LR) method, the proposed sEM-based method performs better on edge preservation, noise suppression, and lesion detection, and demonstrates a potential to estimate the CBF within a shorter scanning time. For in vivo data, the corrected CBF values of gray matter (GM) were independent of the GM probability, thereby indicating the effectiveness of the sEM-based method for the PV correction of the ASL sequence.ConclusionsThis study validates the proposed sEM scheme for the statistical perfusion model of mixed tissues and demonstrates the effectiveness of using inherent perfusion information in the multiple measurements for PV correction of the ASL sequence.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:

- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.