-
- Guanyi Liu, Rongming Xu, Weihu Ma, Shaohua Sun, and Jianxiang Feng.
- Department of Orthopaedic Surgery, Ningbo Sixth Hospital, Ningbo, ZheJiang, People's Republic of China. lgysimon@yahoo.com.cn
- J Neurosurg Spine. 2011 Jan 1; 14 (1): 114-21.
Objectthe object of this study was to determine the safe screw placement technique for cervical transarticular screw fixation.Methodstwenty cadaveric adult cervical spines were studied. All soft tissues surrounding the cervical spinal nerves from C-2 to T-1 were dissected carefully to expose the lateral mass, facet joint, transverse process, vertebral artery (VA), and spinal nerves (ventral and dorsal rami). After the proper entrance and exit points for the transarticular screws were determined, posterior transarticular screw implantation was performed under direct visualization from C2-3 to C5-6. A CT scan was performed to check the screw placement. The angle and length of the transarticular screw trajectory, the distance between the tip of the screw and the VA, and the sagittal safety angle were measured on the CT scan. Statistical analysis was performed using ANOVA (p < 0.05). Sagittal and axial orientations of transarticular screws were carefully analyzed.Resultsthere was no nerve or artery impingement or penetration. The average caudal angle of the screws in the sagittal plane was 37.3° ± 5.0° and the lateral angle in the axial plane was 16.6° ± 4.6°. The average distance between the tip of the screw and the VA (the posterior border of the VA foramen) was 5.8 ± 1.5 mm. The average sagittal safety angle was 41.9° ± 5.6°. No difference was observed according to the vertebral level. The average bone purchase was 18.7 ± 1.4 mm. Bone purchase was significantly greater at C2-3 (23.2 ± 1.6 mm) than at C3-4 through C5-6 (17.2 ± 1.3 mm, p < 0.05).Conclusionsthis study establishes anatomical guidelines to allow for safe cervical transarticular screw insertion. The starting point of transarticular screws should be 1 mm medial to the midpoint of the lateral mass. The "ideal" drilling angle is approximately 37° in the inferior direction and 16° in the lateral direction for the C2-3 through the C5-6 levels. The screw should be directed as laterally as possible in the axial plane without causing the lateral mass to fracture and as caudally as the occipital bone permits in the sagittal plane. The ideal screw size would be 3.5 mm in diameter and 18 mm in length.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.