-
Int J Chron Obstruct Pulmon Dis · Jan 2016
Comparative StudyComparison of pulmonary function in patients with COPD, asthma-COPD overlap syndrome, and asthma with airflow limitation.
- Yoshiaki Kitaguchi, Masanori Yasuo, and Masayuki Hanaoka.
- First Department of Internal Medicine, Shinshu University School of Medicine, Matsumoto, Japan.
- Int J Chron Obstruct Pulmon Dis. 2016 Jan 1; 11: 991-7.
BackgroundThis study was conducted in order to investigate the differences in the respiratory physiology of patients with chronic obstructive pulmonary disease (COPD), asthma-COPD overlap syndrome (ACOS), and asthma with airflow limitation (asthma FL(+)).MethodsThe medical records for a series of all stable patients with persistent airflow limitation due to COPD, ACOS, or asthma were retrospectively reviewed and divided into the COPD group (n=118), the ACOS group (n=32), and the asthma FL(+) group (n=27). All the patients underwent chest high-resolution computed tomography (HRCT) and pulmonary function tests, including respiratory impedance.ResultsThe low attenuation area score on chest HRCT was significantly higher in the COPD group than in the ACOS group (9.52±0.76 vs 5.09±1.16, P<0.01). The prevalence of bronchial wall thickening on chest HRCT was significantly higher in the asthma FL(+) group than in the COPD group (55.6% vs 25.0%, P<0.01). In pulmonary function, forced expiratory volume in 1 second (FEV1) and peak expiratory flow rate were significantly higher in the asthma FL(+) group than in the ACOS group (76.28%±2.54% predicted vs 63.43%±3.22% predicted, P<0.05 and 74.40%±3.16% predicted vs 61.08%±3.54% predicted, P<0.05, respectively). Although residual volume was significantly lower in the asthma FL(+) group than in the COPD group (112.05%±4.34% predicted vs 137.38%±3.43% predicted, P<0.01) and the ACOS group (112.05%±4.34% predicted vs148.46%±6.25% predicted, P<0.01), there were no significant differences in functional residual capacity or total lung capacity. The increase in FEV1 in response to short-acting β2-agonists was significantly greater in the ACOS group than in the COPD group (229±29 mL vs 72±10 mL, P<0.01) and the asthma FL(+) group (229±29 mL vs 153±21 mL, P<0.05). Regarding respiratory impedance, resistance at 5 Hz and resistance at 20 Hz, which are oscillatory parameters of respiratory resistance, were significantly higher in the asthma FL(+) group than in the COPD group at the whole-breath (4.29±0.30 cmH2O/L/s vs 3.41±0.14 cmH2O/L/s, P<0.01 and 3.50±0.24 cmH2O/L/s vs 2.68±0.10 cmH2O/L/s, P<0.01, respectively), expiratory, and inspiratory phases.ConclusionAlthough persistent airflow limitation occurs in patients with COPD, ACOS, and asthma FL(+), they may have distinct characteristics of the respiratory physiology and different responsiveness to bronchodilators.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.