Int. J. Radiat. Oncol. Biol. Phys. · Oct 2000
Postimplant dosimetry for (125)I prostate implants: definitions and factors affecting outcome.
- R G Stock, N N Stone, Y C Lo, N Malhado, J Kao, and J K DeWyngaert.
- Department of Radiation Oncology, Mount Sinai School of Medicine, New York, NY, USA.
- Int. J. Radiat. Oncol. Biol. Phys. 2000 Oct 1; 48 (3): 899-906.
ObjectiveAn analysis of CT-based dosimetry was performed to assess the efficacy of the real time method of prostate implantation, explore the relationship of various dose descriptions and determine implant factors affecting outcome.Methods And MaterialsBetween 7/95 and 8/99, 297 patients underwent (125)I implants for T1-T2 prostate cancer and had CT-based dosimetry performed (TG43 formalism). Dosimetry was performed 1 month postimplant. Using a dose-volume histogram, doses delivered to 100%, 95%, 90%, and 80% of the prostate (D100, D95, D90, D80, respectively) as well as percentages of the gland receiving 240 Gy, 160 Gy, 140 Gy (V240, V160, V140, respectively) were reported. Correlations between the various dose parameters and D90 were generated. The effect of the number of seeds implanted, seeds/volume, prostate volume, experience as assessed by time (8/01/99-date of implant), ultrasound probe (mechanical sector vs. dual phased electronic), and the ratio of the CT dosimetry prostate volume/ultrasound implant volume (CT/US vol) were analyzed.ResultsThe median D100, D95, D90, and D80 values were 10,200 cGy, 15,655 cGy, 17,578 cGy, and 19,873 cGy, respectively. The median V240, V160, and V140 were 56%, 94%, and 98%, respectively. Correlations of dose descriptions found a close relationship of D95, D80, V240, V160, and V140 with D90 with r values of 0.928, 0.973, 0.911, 0.816, and 0.733, respectively. D100 correlated poorly with D90 (r = 0.099). Using a stepwise regression analysis, CT/US vol ratio, prostate volume, and seed number were the only significant factors affecting D90 with CT/US vol ratio having the greatest effect. The dual-phased electronic probe was associated with fewer D90 values of less than 140 Gy (2%) compared to the mechanical sector probe (14%) (p = 0.02).ConclusionCT-based dosimetry results reveal the real-time implant technique to be an effective method of prostate implantation. Factors associated with more precise implantation, such as decreased postimplant edema, new technology, and increased number of seeds will lead to higher D90 values.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.