    Isotope choice and the effect of edema on prostate brachytherapy dosimetry.

    • W M Butler, G S Merrick, A T Dorsey, and J H Lief.
    • Schiffler Oncology Center, Wheeling Hospital, West Virginia 26003-6300, USA.
    • Med Phys. 2000 May 1; 27 (5): 1067-75.

    AbstractIn prostate brachytherapy, post implant dosimetry quality parameters may be strongly affected by edema brought on by the trauma of the implant procedure since the amount of edema and the time course of its resolution are highly variable from patient to patient. Edema was simulated from preplans on three prostates which had ultrasound prostate volumes of 18.7, 40.7 and 60.2 cm3 expanded to planning volumes of 32.9, 60.0 and 87.8 cm3, respectively. The preplans were designed so that identical seed distributions for a given prostate gave virtually identical target dose coverage of 99.7+/-0.3% of the planning volume when using either 125I or 103Pd. Simulated CT edema volume expansions of 0%, 10%, 20% and 30% were imposed anisotropically in accordance with clinical observations so that the expansion in the superior-inferior direction was twice that of the transverse dimensions. Dose-volume histograms (DVHs) were analyzed for each prostate as a function of isotope and degree of edema. The 103Pd implants were more greatly affected by fixed amounts of edema than 125I implants, and the slopes of the DVH curves indicate less homogeneity from 103Pd implants. The DVHs were then weighted according to the portion of the isotope decay curve occupied by each edema step for half-lives of edema resolution of 5, 10 and 20 days which are within the range of clinically observed resolution times. The weighted DVHs were summed to give a net DVH corresponding to the overall dynamic effect of edema. A greater fraction of the defined prostate volume received doses in the range of likely therapeutic significance, from 75% to 125% of the prescribed minimal peripheral dose (mPD), from 125I implants than from 103Pd implants. These differences in dosimetric quality arise from two differences in the physical properties of the isotopes: more rapid attenuation of 103Pd photons with distance creates cool spots in an edematous prostate, and the shorter half-life of 103Pd causes a greater fraction of the isotope decay to consist of the prostate in an edematous state. An increase in 103Pd seed strength by about 10% beyond that required to achieve equal coverage with an identical seed distribution using 125I should minimize the differences brought on by edema.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

Want more great medical articles?

Keep up to date with a free trial of metajournal, personalized for your practice.
1,694,794 articles already indexed!

We guarantee your privacy. Your email address will not be shared.