-
Int. J. Radiat. Oncol. Biol. Phys. · Nov 2001
Quantitative dose-volume response analysis of changes in parotid gland function after radiotherapy in the head-and-neck region.
- J M Roesink, M A Moerland, J J Battermann, G J Hordijk, and C H Terhaard.
- Department of Radiotherapy, University Hospital Utrecht, University Medical Center Utrecht, Utrecht, The Netherlands. JR@radcl.ruu.nl
- Int. J. Radiat. Oncol. Biol. Phys. 2001 Nov 15; 51 (4): 938-46.
PurposeTo study the radiation tolerance of the parotid glands as a function of dose and volume irradiated.Methods And MaterialsOne hundred eight patients treated with primary or postoperative radiotherapy for various malignancies in the head-and-neck region were prospectively evaluated. Stimulated parotid flow rate was measured before radiotherapy and 6 weeks, 6 months, and 1 year after radiotherapy. Parotid gland dose-volume histograms were derived from CT-based treatment planning. The normal tissue complication probability model proposed by Lyman was fit to the data. A complication was defined as stimulated parotid flow rate <25% of the preradiotherapy flow rate.ResultsThe mean stimulated preradiotherapy flow rate of 174 parotid glands was 0.34 mL/min. The mean flow rate reduced to 0.12 mL/min 6 weeks postradiotherapy, but recovered to a mean flow rate of 0.20 mL/min at 1 year after radiotherapy. Reduction in postradiotherapy flow rate correlated significantly with mean parotid dose. No threshold dose was found. Increasing the irradiated volume of parotid glands from 0%-40% to 90-100% in patients with a mean parotid dose of 35-45 Gy resulted in a decrease in flow ratio from, respectively, approximately 100% to less than 10% 6 weeks after radiation. The flow ratio of the 90%-100% group partially recovered to 15% at 6 months and to 30% at 1 year after radiotherapy. The normal tissue complication probability model parameter TD(50) (the dose to the whole organ leading to a complication probability of 50%) was found to be 31, 35, and 39 Gy at 6 weeks, 6 months, and 1 year postradiotherapy, respectively. The volume dependency parameter n was around 1, which means that the mean parotid dose correlates best with the observed complications. There was no steep dose-response curve (m = 0.45 at 1 year postradiotherapy).ConclusionsThis study on dose/volume/parotid gland function relationships revealed a linear correlation between postradiotherapy flow ratio and parotid gland dose and a strong volume dependency. No threshold dose was found. Recovery of parotid gland function was shown at 6 months and 1 year after radiotherapy. In radiation planning, attempts should be made to achieve a mean parotid gland dose at least below 39 Gy (leading to a complication probability of 50%).
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.