• Br J Anaesth · Jan 2012

    Randomized Controlled Trial

    Simulated evaluation of a non-Luer safety connector system for use in neuraxial procedures.

    • R Onia, Y Wu, V Parvu, I Eshun-Wilson, and K Kassler-Taub.
    • Becton, Dickinson and Company, 9450 South State Street, Sandy, UT 84070, USA. rudy_onia@bd.com
    • Br J Anaesth. 2012 Jan 1;108(1):134-9.

    BackgroundSpinal syringes, needles, and other devices with connectors that will not also connect with Luer devices could substantially reduce wrong-route drug administration errors. This study aimed to evaluate a newly designed non-Luer safety connector system for neuraxial procedures in terms of clinical acceptability and cross-connectivity with conventional Luer devices.MethodsA non-Luer safety connector system (BD UniVia-6 Safety Connector system), which included non-Luer spinal needles, syringes, and blunt fill filter needles, was evaluated in a prospective, simulated use, randomized study. Clinicians evaluated the acceptability and performance characteristics using a normal saline injectate on an artificial back model.ResultsForty-nine clinicians participated in the study. For 93 of 98 spinal injection procedures, clinicians agreed that overall, the safety system was clinically acceptable (94.9%; 95% lower bound 89.6%). Forty-eight clinicians (98%; 95% lower bound: 90.7%) agreed that the safety system prevented or reduced the risk of misconnection between a conventional syringe and a safety spinal needle. A lower proportion (63.3%; 95% lower bound: 50.5%) agreed that the safety system would prevent or reduce the risk of misconnections between a safety syringe filled with medication intended for spinal injection and an i.v. Luer device.ConclusionsOur study demonstrated that study clinicians found the safety system to be acceptable with minimal impact on technique in a simulated-use setting. The non-Luer system also appeared to decrease the risk of administration of i.v. medications into the intrathecal space. Further modifications will be required to completely eliminate the risk of administering intrathecal medication i.v. and evaluation in a clinical setting will help determine the true impact of this non-Luer system on patient safety.

      Pubmed     Free full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

Want more great medical articles?

Keep up to date with a free trial of metajournal, personalized for your practice.
1,694,794 articles already indexed!

We guarantee your privacy. Your email address will not be shared.