Int. J. Radiat. Oncol. Biol. Phys. · Dec 2000
Decreasing the dosimetric effects of misalignment when using a mono-isocentric technique for irradiation of head and neck cancer.
- P L Fabrizio, E C McCullough, and R L Foote.
- Division of Radiation Oncology, Mayo Clinic and Mayo Foundation, Rochester, MN 55905, USA.
- Int. J. Radiat. Oncol. Biol. Phys. 2000 Dec 1; 48 (5): 1623-34.
PurposeThe purpose of this study was to quantify and develop methods to decrease inhomogeneities created with field edge mismatch when using a mono-isocentric beam-split technique.Methods And MaterialsWe validated techniques to determine dose across a half-blocked field edge and quantified potential sources of systematic matchline error. Then, two methods were used to evaluate matchline doses. The first used film dosimetry data from a half-beam field and a spreadsheet. Duplication and reversal provided two columns, each representing a beam-split field edge. Summation simulated perfect abutment and shifting created various gaps and overlaps. The second method involved obtaining dose profiles at midfield along the ray perpendicular to abutted, overlapped, and gapped beam-split fields on six linear accelerators. To enlarge the penumbra, we designed several field edge modifiers, then re-evaluated matchline doses. The field edge modifiers applicability to a 3-field head and neck treatment technique was also examined.ResultsFilm-determined dose profiles provide similar information across a beam-split field edge as an ionization chamber. With the mono-isocentric beam-split technique, a 4-mm overlap or gap produces inhomogeneities nearly 60% above or below the intended dose. A 2-mm overlap or gap produces inhomogeneities nearly 30% above or below the intended dose. A customized penumbra generator decreased the magnitude of these inhomogeneities to 20% and 10%, respectively.ConclusionThe two methods of evaluating matchline dose described above gave similar results. When using the mono-isocentric half-field technique, small misalignments produce worrisome regions of inhomogeneity. Our penumbra generator substantially decreases the magnitude of the dose inhomogeneities, although the volume receiving an inhomogeneous dose increases.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.