Controlled Clinical Trial
Non-invasive haemoglobin measurement in patients undergoing elective Caesarean section.
- Department of Anaesthesia, Stanford University School of Medicine, Stanford CA 94305, USA. ajbut@stanford.edu
- Br J Anaesth. 2012 Feb 1;108(2):271-7.
BackgroundThe ability to measure haemoglobin (Hb) real-time and non-invasively offers important clinical value in the assessment of acute changes in maternal Hb during the peripartum period. This study evaluates the Masimo Rainbow SET(®) Radical-7 Pulse CO-Oximeter in a pregnant population undergoing Caesarean section (CS).MethodsFifty patients undergoing elective CS were enrolled in this prospective, controlled study and followed for 48 h after surgery. Non-invasive Masimo Hb (SpHb) values were compared with laboratory Hb values from venous blood samples drawn at baseline, immediately post-CS, and 24 h post-CS using the Bland-Altman plots. Longitudinal analysis of SpHb changes over time was performed using mixed-effects regression modelling.ResultsFor the comparison between SpHb and laboratory Hb, SpHb displayed a significant positive bias at baseline {1.22 g dl(-1) [95% confidence interval (CI): 0.89-1.54]} and at 24 h post-CS [1.36 g dl(-1) (95% CI: 1.04-1.68)]. The bias immediately post-CS was 0.14 g dl(-1) (95% CI: -0.18 to 0.46). The limits of agreement at baseline, immediately post-CS, and at 24 h post-CS were: -0.9 and 3.33, -2.35 and 2.56, and -0.55 and 3.27 g dl(-1), respectively. The mean decrease in SpHb from baseline to 48 h post-CS was ∼1 g dl(-1).ConclusionsThe variability in bias and limits of agreements of the Rainbow SET(®) Radical-7 Pulse CO-Oximeter SpHb may limit its clinical utility for assessing Hb concentration in patients undergoing elective CS. Modifications are needed in the calibration of the device to improve accuracy and precision in an obstetric setting. The study was registered at clinicaltrials.gov (NCT01108471) before participant enrolment: URL=http://clinicaltrials.gov/ct2/show/NCT01108471?term=butwick&rank=1.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:

- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.