AJNR Am J Neuroradiol · Jul 2017
Mechanical Thrombectomy with the Embolus Retriever with Interlinked Cages in Acute Ischemic Stroke: ERIC, the New Boy in the Class.
- H Steglich-Arnholm, D Kondziella, A Wagner, M E Cronqvist, K Hansen, T C Truelsen, L-H Krarup, J L S Højgaard, S Taudorf, H K Iversen, D W Krieger, and M Holtmannspötter.
- From the Departments of Neurology (H.S.-A., D.K., K.H., T.C.T., L.-H.K., J.L.S.H., S.T., H.K.I.) henrik.steglich@gmail.com.
- AJNR Am J Neuroradiol. 2017 Jul 1; 38 (7): 1356-1361.
Background And PurposeThe Embolus Retriever with Interlinked Cages (ERIC) device is a novel stent retriever for mechanical thrombectomy. It consists of interlinked cages and could improve procedural benchmarks and clinical outcome compared with classic stent retrievers. This study compares the rates of recanalization, favorable clinical outcome, procedural adverse events, and benchmarks between the ERIC device and classic stent retrievers.Materials And MethodsFrom 545 patients treated with thrombectomy between 2012 and 2015, 316 patients were included. The mean age was 69 ±13 years, the mean baseline NIHSS score was 17 ± 5, and 174 (55%) were men. The ERIC was used as the primary thrombectomy device in 59 (19%) patients. In a propensity score matched analysis including the NIHSS score, clot location, delay to groin puncture, neurointerventionalist, and anesthetic management, 57 matched pairs were identified.ResultsPatients treated with the ERIC device compared with classic stent retrievers showed equal rates of recanalization (86% versus 81%, P = .61), equal favorable 3-month clinical outcome (mRS 0-2: 46% versus 40%, P = .71), and procedural adverse events (28% versus 30%, P = 1.00). However, in patients treated with the ERIC device, thrombectomy procedures were less time-consuming (67 versus 98 minutes, P = .009) and a rescue device was needed less often (18% versus 39%, P = .02) compared with classic stent retrievers.ConclusionsMechanical thrombectomy with the ERIC device is effective and safe. Rates of favorable procedural and clinical outcomes are at least as good as those with classic stent retrievers. Of note, the ERIC device might be time-saving and decrease the need for rescue devices. These promising results call for replication in larger prospective clinical trials.© 2017 by American Journal of Neuroradiology.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.