• Clin. Orthop. Relat. Res. · Jun 2021

    Custom Implants in TKA Provide No Substantial Benefit in Terms of Outcome Scores, Reoperation Risk, or Mean Alignment: A Systematic Review.

    • Eran Beit Ner, Saad Dosani, Leela C Biant, and Gwenllian Fflur Tawy.
    • E. Beit Ner, Department of Orthopedic Surgery, Yitzhak Shamir Medical Center, Zerifin, Israel, affiliated with the Sackler Faculty of Medicine, Tel-Aviv University, Tel-Aviv, Israel.
    • Clin. Orthop. Relat. Res. 2021 Jun 1; 479 (6): 1237-1249.

    BackgroundFailure to accurately replicate the native anatomy and biomechanics of the knee has been suggested to contribute to dissatisfaction after TKA. Custom implants promise a personalized surgical approach, with the aim of improving patient satisfaction and pain as well as lowering revision rates. However, some published research on custom TKA implants has found no clinically important improvements in postoperative validated outcomes scores, risks of revision or reoperation, and implant alignment. In the interest of helping to settle this controversy, a systematic review seems warranted.Question/PurposeIn this systematic review, we asked whether custom implants result in clinically important improvements over conventional off-the-shelf implants for anatomically uncomplicated primary TKA in terms of (1) validated outcomes scores, (2) the risk of revision or reoperation, and (3) implant alignment.MethodsThe US National Library of Medicine (PubMed/Medline), Embase, Web of Science, and Cochrane Database of Systematic Reviews were systematically searched to identify publications from the past 10 years relevant to this review. Publications that compared the clinical outcome measures, number of revisions and reoperations, and radiological assessment of implant alignment of custom and standard implants with validated endpoints were eligible for inclusion. In the interest of capturing as much potentially relevant information as possible, we applied no requirement for minimum follow-up duration. Clinical outcomes were assessed using patient-reported outcome (PROM) scores including the Knee Society Score (KSS), Forgotten Joint Score, and Knee Injury and Osteoarthritis Outcome Score. The risk for revision or reoperation were evaluated by the number of early and late manipulations, debridement procedures, and replacement of one or more components. Implant alignment was compared using postoperative deviation from the neutral (0°) mechanical axis of the limb and each component and the posterior tibial slope. All qualified studies were retrospective, and all compared custom implants with standard implants. Data on 1510 patients were reviewed (749 with custom implants and 761 with off-the-shelf implants). The mean follow-up time ranged from 12 to 33 months.ResultsThere was no apparent advantage to custom implants in terms of PROM scores. Of the five studies evaluating clinical outcomes, only one reported better KSS-Function scores at 3 months; two reported no difference, and two found inferior KSS scores. In several studies, custom implants were associated with more frequent reoperations than standard implants. Although in general there were no differences between custom and standard implants in terms of mean coronal plane limb alignment, one of seven studies found that the proportion of patients whose alignment was outside ± 3° from the neutral axis in the coronal plane was lower in the custom group than in the standard group.ConclusionWith generally poorer outcomes scores for pain and function, generally higher risks of reoperation and reintervention, and no overall benefit to alignment, custom implants for primary TKA for the general population currently appear to be inferior to standard implants. Whether the slight reduction in the proportion of patients with alignment outliers observed in a minority of studies will result in a substantial reduction in revision risk over time must be addressed by future studies. However, until or unless such a reduction is proven, we recommend against the routine use of custom implants in practice because of increased costs and the risks associated with their novelty.Level Of EvidenceLevel III, therapeutic study.Copyright © 2021 by the Association of Bone and Joint Surgeons.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…