-
Knee Surg Sports Traumatol Arthrosc · May 2019
A high level of satisfaction after bicompartmental individualized knee arthroplasty with patient-specific implants and instruments.
- Takahiro Ogura, Kiet Le, Gergo Merkely, Tim Bryant, and Tom Minas.
- Sports Medicine Center, Funabashi Orthopaedic Hospital, 1-833 Hasama, Funabashi, Chiba, 274-0822, Japan.
- Knee Surg Sports Traumatol Arthrosc. 2019 May 1; 27 (5): 1487-1496.
PurposeCustomized Individually Made (CIM) Bicompartmental Knee Arthroplasty (BKA) implants and three-dimensional printed customized instruments are available to fit to each patient's unique anatomy, medial or lateral with patellofemoral. This study aimed to evaluate the clinical outcomes after CIM-BKA.MethodsFifty-five patients [59 knees; average age, 51 years; standard deviation (SD), 6.8; range 37-65 years] who underwent CIM-BKA were evaluated over an average of 3.8-year follow-up (SD 1.6; range 1-6 years). Forty-one knees underwent BKA combined medial and patellofemoral replacement (BKA-MP) and 18 knees underwent BKA combined lateral with patellofemoral replacement (BKA-LP). Survival rates, the modified Cincinnati Knee Rating Scale, WOMAC, VAS, SF-36, a satisfaction survey, and radiographic evaluation were used to evaluate outcomes.ResultsOverall, survival rates were 98% and 92% at 2 and 5 years, respectively. Of 56 knees (95%) that did not fail, all patient-reported functional scores significantly improved post-operatively (P < 0.01), regardless of the previous surgeries, with a high level of satisfaction (51/56 knees, 91%). Radiographically, all the femoral components fit perfectly and 56 knees (95%) of the tibial components fit with less than 2 mm of undercoverage or overhang. Three knees (5%) required the conversion to TKA and 17 knees (29%) required subsequent surgical procedures, of which multiply operated knees had higher rate than virgin knee [14/40 (35%) vs. 3/16 (19%)].ConclusionCIM-BKA allowed precise fit of the components and provided a significant improvement post-operatively with a high level of satisfaction over short- to mid-term follow-up. This novel CIM-BKA is resurfacing, and does not require 10-mm faceted cuts, being only 3-mm-thick, which preserves bone stock for the future. It may be a promising option for relatively young active patients with bicompartmental osteoarthritis with a longer term follow-up being necessary.Level Of EvidenceIV.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.