• Anesthesia and analgesia · Aug 2021

    Comparative Study

    Fiber-Needle Swept-Source Optical Coherence Tomography for the Real-Time Visualization of the Transversus Abdominis Plane Block Procedure in a Swine Model.

    • Wei-Nung Teng, Meng-Chun Kao, Chien-Kun Ting, and Wen-Chuan Kuo.
    • From the Department of Anesthesiology, Taipei Veterans General Hospital and.
    • Anesth. Analg. 2021 Aug 1; 133 (2): 526-534.

    BackgroundFascia blocks (eg, the transversus abdominis plane [TAP] block) target the intermuscular fascia layers. Ultrasound techniques have allowed peripheral blocks to be performed with accuracy and safety, however, with limitations. Optical coherence tomography (OCT) is based on low-coherence interferometry. In this study, we examined the ability of OCT to identify the TAP.MethodsA swept-source OCT probe was placed in a 17-gauge needle to obtain imaging. The needle was inserted within 2 different angle ranges (0°-30° and 30°-60°) on a slice of pork belly to assess imaging characteristics. A series of real-time OCT imaging of the muscle, fascia, and interfascial space was obtained. The tissue location of the needle tip was identified using near-infrared (NIR) imaging. In vivo OCT imaging was further done on 3 female 6-month-old native Chinese Landrance Duroc pigs. Real-time images of tissue layers were obtained with needle insertion. Ultrasound imaging of the OCT needle probe was also performed at the same time for needle trajectory guidance. After imaging, the OCT probe was removed, and 5 mL of normal saline was injected via the needle to confirm correct fascia plane identification.ResultsIn and ex vivo studies showed clear visual distinction of muscle, fascia, and interfascial layer with OCT, with limitations. Independent validation of OCT criteria for the muscle/fascia differentiation by 20 OCT readers for the in vivo data demonstrated the sensitivity = 0.91, specificity = 0.90, and accuracy = 0.89. Although the angle of needle entry affected the depth of OCT penetration in the muscle, the attenuation coefficient values of the fascia and muscle tissue were statistically different (P < .001) and with high area under the receiver operating characteristics (ROC) curve (AUC) (AUC = 0.93 in 0°-30° and AUC = 1 in 30°-60°) for fascia identification.ConclusionsThis study introduced a novel needle imaging probe method to identify the transversus abdominis fascia plane in real-time. Quantitative calculation of the attenuation coefficients can further aid objective identification by providing direct confirmation of the tip position, increasing the first-pass success rate, and decreasing the need for needle repositioning. Combining OCT and ultrasound may improve the accuracy of anesthetics placement.Copyright © 2020 International Anesthesia Research Society.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

What will the 'Medical Journal of You' look like?

Start your free 21 day trial now.

We guarantee your privacy. Your email address will not be shared.