-
Neurol Neurochir Pol · Jul 2010
Neuroform stent-assisted coil embolization: a new treatment strategy for complex intracranial aneurysms. Results of medium length follow-up.
- Ali Ismail Alhothi, Tiewei Qi, Shaolei Guo, Zhongsong Shi, Feng Liang, Lixuan Yang, and Zhengsong Huang.
- Department of Neurosurgery, First Affiliated Hospital, Sun Yatsen University, Guangzhou 510080, People's Republic of China.
- Neurol Neurochir Pol. 2010 Jul 1; 44 (4): 366-74.
Background And PurposeWe present detailed results of using Neuroform stent-assisted coil embolization to treat complex cerebral aneurysms over a three-year period.Material And MethodsOnly patients who underwent Neuroform stent-assisted coil embolization were included in this study. We assessed patients' history, aneurysm morphology, indications for stenting, and technical details of the procedures, as well as complications and the midterm follow-up data.ResultsThis study included 26 patients with 39 aneurysms. A total of 32 of 39 aneurysms were treated by Neuroform stent-assisted embolization (SAC), whereas 3 aneurysms were stented without coiling, 2 aneurysms coiled without stenting and 2 aneurysms surgically clipped. The indications for use of stent included broad-neck aneurysms (n = 28), giant or large aneurysms (n = 6), and fusiform aneurysms (n = 5). Of the 32 aneurysms treated with Neuroform SAC, we achieved complete (100%) and near complete (> 95%) occlusion in 27 aneurysms, and partial (< 95%) occlusion in 5 aneurysms. Follow-up angiographic data available in 22 of 32 aneurysms treated with Neuroform SAC (68.7%) demonstrated recanalization in 3 aneurysms (13.6%), and stable occlusion in 19 aneurysms (86.4%). There was no delayed progressive embolization or in-stent stenosis.ConclusionsDirect and midterm follow-up results confirmed that Neuroform stent-assisted coil embolization was a safe and effective technique in the treatment of complex cerebral aneurysms. Although clinically significant complications were uncommon and the evaluation at midterm follow-up is encouraging, further studies need to assess the long-term stability and durability of the stent.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.