-
- Ranjodh Dhami, Shigang Wang, Allen R Kunselman, and Akif Ündar.
- Department of Pediatrics, Penn State Hershey Pediatric Cardiovascular Research Center, Penn State Hershey Children's Hospital, Hershey, PA, USA.
- Artif Organs. 2014 Jan 1; 38 (1): 56-63.
AbstractCardiopulmonary bypass (CPB) is used for a variety of procedures in pediatric patients. Flow settings of the CPB pump have dramatic effects on patient outcome, and gaseous microemboli delivery within the CPB circuit has been linked to neurological complications. To ensure the ongoing improvement of pediatric CPB, consistent evaluation and improvement of the equipment is necessary. In this study we analyze the Jostra HL-20 roller pump (Jostra USA, Austin, TX, USA) and a Medos Deltastream DP3 diagonal pump (MEDOS Medizintechnik AG, Stolberg, Germany) which has not yet received Food and Drug Administration approval. An infant CPB model with heparinized human blood is used to quantify the gaseous microemboli delivery (via an Emboli Detection and Classification Quantifier), as well as the hemodynamic energy delivered under flow rates of 400, 800, and 1200 mL/min. Results show that at most flow settings the DP3 delivers fewer microemboli than the Jostra roller pump at the pre-oxygenator site, with an exception at 1200 mL/min under pulsatile mode. The total volume and the number of gaseous microemboli greater than 40 μm in diameter were lower in the DP3 group. The HL-20 exhibits less stolen blood flow (except at 1200 mL/min) and oxygenator pressure drops in both pulsatile and nonpulsatile mode. Additionally, under pulsatile flow the DP3 delivers greater surplus hemodynamic energy. Both pumps produce relatively few microemboli and deliver adequate hemodynamic energy to the pseudo-patient, with the DP3 performing slightly better under most flow settings. © 2013, Copyright the Authors. Artificial Organs © 2013 Wiley Periodicals, Inc. and International Center for Artificial Organs and Transplantation.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.