-
J. Cardiovasc. Electrophysiol. · Jan 2010
The optimal automatic algorithm for the mapping of complex fractionated atrial electrograms in patients with atrial fibrillation.
- Wen-Chin Tsai, Yenn-Jiang Lin, Hsuan-Ming Tsao, Shih-Lin Chang, Li-Wei Lo, Yu-Feng Hu, Chien-Jung Chang, Wei-Hua Tang, Ta-Chun Tuan, Ameya R Udyavar, Hi-Hung Wang, and Shih-Ann Chen.
- Division of Cardiology, Department of Medicine, Taipei Veterans General Hospital, Taipei, Taiwan.
- J. Cardiovasc. Electrophysiol. 2010 Jan 1; 21 (1): 21-6.
AbstractCFAEs and the Voltage. Introduction: Catheter ablation of atrial fibrillation (AF) can be guided by the identification of complex fractionated atrial electrograms (CFAEs). We aimed to study the prediction of the CFAEs defined by an automatic algorithm in different atrial substrates (high voltage areas vs low voltage areas). Methods and Results: This study included 13 patients (age = 56 +/- 12 years, paroxysmal AF = 8 and persistent AF = 5), who underwent mapping and catheter ablation of AF with a NavX system. High-density voltage mapping of the left atrium (LA) was performed during sinus rhythm (SR) (248 +/- 75 sites per patient) followed by that during AF (88 +/- 24 sites per patient). The CFAE maps were based on the automatic-detection algorithm. "Operator-determined CFAEs" were defined according to Nademannee's criteria. A low-voltage zone (LVZ) was defined as a bipolar voltage of less than 0.5 mV during SR. Among a total of 1150 mapping sites, 459 (40%) were categorized as "operator-determined CFAE sites," whereas 691 (60%) were categorized as "operator-determined non-CFAE sites." The sensitivity and negative predictive value increased as the fractionated interval (FI) value of the automatic algorithm increased, but the specificity and positive predictive value decreased. The automatic CFAE algorithm exhibited the highest combined sensitivity and specificity with an FI of <60 ms for the sites inside the LVZ and FI < 70 ms for the sites outside the LVZ, when compared with a single threshold for both the high- and low-voltage groups combined (i.e., no regard for voltage) (ROC: 0.89 vs 0.86). Conclusions: The clinical relevance of the CFAE map would be improved if the calculated index values were accordingly scaled by the electrogram peak-to-peak amplitude.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.