    Assessment and reproducibility of aortic atherosclerosis magnetic resonance imaging: impact of 3-Tesla field strength and parallel imaging.

    • Christopher D Maroules, Roderick McColl, Amit Khera, and Ronald M Peshock.
    • Department of Radiology, Division of Cardiology, Donald W. Reynolds Cardiovascular Clinical Research Center, University of Texas Southwestern Medical Center, Dallas, Texas 75390-8896, USA.
    • Invest Radiol. 2008 Sep 1; 43 (9): 656-62.

    ObjectivesTo investigate image quality and interstudy reproducibility of aortic atherosclerosis imaging at 1.5 T, and to explore the impact of parallel imaging techniques at 3 T.Materials And MethodsInstitutional review board approval and informed consent were obtained. Thirty-two subjects (20 normal, 12 patients with impaired cardiac function) underwent 4 black-blood T2-weighted imaging studies of the abdominal aorta: 2 conventional studies at 1.5 T, a conventional study at 3 T, and an accelerated 3-T study with parallel imaging (SENSE). Contrast-to-noise ratio and image quality score (1-5 scale, 5 = highest quality) were determined for each study. Studies were analyzed for mean wall thickness and area plaque burden as endpoints for aortic atherosclerosis. Bland-Altman analyses were performed to determine interstudy reproducibility between imaging methods. Wilcoxon signed-rank tests were used to identify significant differences between methods (P < 0.05).ResultsImage quality scores were comparable between 1.5 T and 3 T with SENSE (4.0 +/- 0.6 vs. 4.2 +/- 0.6, P = 0.21). Bland-Altman reproducibility for mean wall thickness was -0.03 mm +/- 0.15 (1.5 T vs. 1.5 T), 0.01 mm +/- 0.17 (1.5 T vs. 3 T without SENSE), and -0.01 mm +/- 0.18 (1.5 T vs. 3 T with SENSE), P = 0.83. Detection of the presence or absence of plaque was comparable. Bland-Altman reproducibility for area plaque burden was -0.02% +/- 0.32% (1.5 T vs. 1.5 T), 0.06% +/- 0.41% (1.5 T vs. 3 T without SENSE), and 0.11% +/- 0.33% (1.5 T vs. 3 T with SENSE), P = 0.41.ConclusionBlack-blood MR imaging of aortic atherosclerosis is very reproducible. Parallel imaging at 3 T permits shorter scan time compared with conventional 1.5-T imaging with comparable measures of atherosclerosis extent.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

What will the 'Medical Journal of You' look like?

Start your free 21 day trial now.

We guarantee your privacy. Your email address will not be shared.