• Magn Reson Med · Mar 2019

    On the sensitivity of quantitative susceptibility mapping for measuring trabecular bone density.

    • Maximilian N Diefenbach, Jakob Meineke, Stefan Ruschke, Thomas Baum, Alexandra Gersing, and Dimitrios C Karampinos.
    • Department of Diagnostic and Interventional Radiology, Technical University of Munich, Munich, Germany.
    • Magn Reson Med. 2019 Mar 1; 81 (3): 1739-1754.

    PurposeTo develop a methodological framework to simultaneously measure R 2 * and magnetic susceptibility in trabecularized yellow bone marrow and to investigate the sensitivity of Quantitative Susceptibility Mapping (QSM) for measuring trabecular bone density using a non-UTE multi-gradient echo sequence.MethodsThe ankle of 16 healthy volunteers and two patients was scanned using a time-interleaved multi-gradient-echo (TIMGRE) sequence. After field mapping based on water-fat separation methods and background field removal based on the Laplacian boundary value method, three different QSM dipole inversion schemes were implemented. Mean susceptibility values in regions of different trabecular bone density in the calcaneus were compared to the corresponding values in the R 2 * maps, bone volume to total volume ratios (BV/TV) estimated from high resolution imaging (in 14 subjects), and CT attenuation (in two subjects). In addition, numerical simulations were performed in a simplified trabecular bone model of randomly positioned spherical bone inclusions to verify and compare the scaling of R 2 * and susceptibility with BV/TV.ResultsDifferences in calcaneus trabecularization were well depicted in susceptibility maps, in good agreement with high-resolution MR and CT images. Simulations and in vivo scans showed a linear relationship of measured susceptibility with BV/TV and R 2 * . The ankle in vivo results showed a strong linear correlation between susceptibility and R 2 * (R2  = 0.88, p < 0.001) with a slope and intercept of -0.004 and 0.2 ppm, respectively.ConclusionsA method for multi-paramteric mapping, including R 2 * -mapping and QSM was developed for measuring trabecularized yellow bone marrow, showing good sensitivity of QSM for measuring trabecular bone density.© 2018 The Authors Magnetic Resonance in Medicine published by Wiley Periodicals, Inc. on behalf of International Society for Magnetic Resonance in Medicine.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…