• Magn Reson Med · Jan 2020

    Comparative Study

    Cerebral OEF quantification: A comparison study between quantitative susceptibility mapping and dual-gas calibrated BOLD imaging.

    • Yuhan Ma, Hongfu Sun, Junghun Cho, Erin L Mazerolle, Yi Wang, and G Bruce Pike.
    • McConnell Brain Imaging Centre, Montreal Neurological Institute, McGill University, Montreal, Quebec, Canada.
    • Magn Reson Med. 2020 Jan 1; 83 (1): 68-82.

    PurposeTo compare regional oxygen extraction fraction (OEF) and cerebral metabolic rate of oxygen consumption (CMRO2 ) quantified from the microvascular quantitative susceptibility mapping (QSM) using a hypercapnic gas challenge with those measured by the dual-gas calibrated BOLD imaging (DGC-BOLD) in healthy subjects.MethodsTen healthy subjects were scanned using a 3T MR system. The QSM data were acquired with a multi-echo gradient-echo sequence at baseline and hypercapnia. Cerebral blood flow data were acquired using the pseudo-continuous arterial spin labeling technique. Baseline OEF and CMRO2 were calculated using QSM and cerebral blood flow measurements. The DGC-BOLD data were also collected under a hypercapnic and a hyperoxic condition to yield baseline OEF and CMRO2 . The QSM-OEF and CMRO2 maps were compared with DGC-BOLD OEF and CMRO2 maps using region of interest (vascular territories) analysis and Bland-Altman plots.ResultsHypercapnia is a robust stimulus for mapping OEF in combination with QSM. Average OEF in 16 vascular territory regions of interest across 10 subjects was 0.40 ± 0.04 by QSM-OEF and 0.38 ± 0.09 by DGC-BOLD. The average CMRO2 was 176 ± 35 and 167 ± 53 μmol O2 /min/100g by QSM-OEF and DGC-BOLD, respectively. A Bland-Altman plot of regional OEF and CMRO2 in regions of interest revealed a statistically significant but small difference (OEF difference = 0.02, CMRO2 difference = 9 μmol O2 /min/100g, p < .05) between the 2 methods for the 10 healthy subjects.ConclusionHypercapnic challenge-assisted QSM-OEF is a feasible approach to quantify regional brain OEF and CMRO2 . Compared with DGC-BOLD, hypercapnia QSM-OEF results in smaller intersubject variability and requires only 1 gas challenge.© 2019 International Society for Magnetic Resonance in Medicine.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…