• Magn Reson Med · Dec 2018

    Hyperpolarized 129 Xe gas transfer MRI: the transition from 1.5T to 3T.

    • Ziyi Wang, Mu He, Elianna Bier, Leith Rankine, Geoffry Schrank, Sudarshan Rajagopal, Yuh-Chin Huang, Christopher Kelsey, Samantha Womack, Joseph Mammarappallil, and Bastiaan Driehuys.
    • Department of Biomedical Engineering, Duke University, Durham, North Carolina.
    • Magn Reson Med. 2018 Dec 1; 80 (6): 2374-2383.

    PurposeHyperpolarized 129 Xe MRI depicting 3D ventilation, interstitial barrier uptake, and transfer to red blood cells (RBCs) has emerged as a powerful new means of detecting pulmonary disease. However, given the challenging susceptibility environment of the lung, such gas transfer imaging has, thus far, only been implemented at 1.5T. Here, we seek to demonstrate the feasibility of Dixon-based 129 Xe gas transfer MRI at 3T.MethodsSeven healthy subjects and six patients with pulmonary disorders were recruited to characterize 129 Xe spectral structure, optimize acquisition parameters, and acquire representative images. Imaging used randomized, gradient-spoiled 3D-radial encoding of 1000 gas (0.5° flip) and dissolved (20° flip) views, reconstructed into 3-mm isotropic voxels. The center of k-space was sampled when barrier and RBC compartments were 90° out of phase (TE90 ). A single dissolved phase spectrum was appended to the sequence to measure the global RBC-barrier ratio for Dixon-based decomposition.ResultsA 0.69 ms sinc was found to generate minimal off-resonance gas-phase excitation (3.0 ± 0.3% of the dissolved-phase), yielding a TE90  = 0.47 ± 0.02 ms. The RBC and barrier resonance frequencies were shifted by 217.6 ± 0.6 ppm and 197.8 ± 0.2 ppm. The RBC http://www.w3.org/1998/Math/MathML"> T 2 * was estimated to be ∼1.1 ms, and therefore each read-out was limited to 1.3 ms. 129 Xe gas and dissolved-phase images have sufficient SNR to produce gas transfer maps of similar quality and sensitivity to pathology, as previously obtained at 1.5T.ConclusionsDespite short dissolved-phase http://www.w3.org/1998/Math/MathML"> T 2 * , 129 Xe gas transfer MRI is feasible at 3T.© 2018 International Society for Magnetic Resonance in Medicine.

      Pubmed     Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…