• Magn Reson Med · Dec 2018

    Diffusion tensor imaging of human Achilles tendon by stimulated echo readout-segmented EPI (ste-RS-EPI).

    • Kenneth Wengler, Dharmesh Tank, Takeshi Fukuda, James M Paci, Mingqian Huang, Mark E Schweitzer, and Xiang He.
    • Department of Biomedical Engineering, Stony Brook University, Stony Brook, New York.
    • Magn Reson Med. 2018 Dec 1; 80 (6): 2464-2474.

    PurposeHealing, regeneration, and remodeling of the injured Achilles tendon are associated with notable changes in tendon architecture. However, assessing Achilles microstructural properties with conventional diffusion tension imaging (DTI) remains a challenge because of very short T2 / http://www.w3.org/1998/Math/MathML"> T 2 * values of the tendon. Hence, the objective of this study was to develop a novel Achilles tendon DTI protocol for a non-invasive investigation of the changes of microstructural integrity in tendinopathy.MethodsA novel stimulated echo readout-segmented EPI (ste-RS-EPI) DTI sequence was proposed to achieve a TE of ∼14-20 ms for typical b-values of 400-800 s/mm2 on clinical 3T MRI scanners. To further boost tendon MR signal, the Achilles was positioned at the magic angle (∼55 °) with respect to the scanner B0 field. The sensitivity of the developed protocol was evaluated in 19 healthy participants and 6 patients with clinically confirmed tendinopathy.ResultsCompared to spin echo RS-EPI DTI protocol, ste-RS-EPI provided an ∼100-200% increase in Achilles MR signal. Tendinopathic Achilles demonstrated a high degree of microstructural disruption based on DTI tractography analysis, with significantly lower (P < 0.05) axial diffusivity (1.20 ± 0.19 vs. 1.39 ± 0.10 × 10-3 mm2 /s), radial diffusivity (0.72 ± 0.11 vs. 0.81 ± 0.08 × 10-3 mm2 /s), and mean diffusivity (0.87 ± 0.14 vs. 1.00 ± 0.07 × 10-3 mm2 /s), but no significant difference in fractional anisotropy (0.38 ± 0.04 vs. 0.38 ± 0.05; P = 0.86).ConclusionAchilles tendon ste-RS-EPI DTI can non-invasively detect the tendinopathy-induced changes to microstructural integrity, consistent with the disruption of collagen arrangement and increased cellularity. This study demonstrated the robustness and sensitivity of the proposed protocol in Achilles tendinopathy.© 2018 International Society for Magnetic Resonance in Medicine.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…