    Decoupling Between Diastolic Pulmonary Artery Pressure and Pulmonary Capillary Wedge Pressure as a Prognostic Factor After Continuous Flow Ventricular Assist Device Implantation.

    • Teruhiko Imamura, Ben Chung, Ann Nguyen, Daniel Rodgers, Gabriel Sayer, Sirtaz Adatya, Nitasha Sarswat, Gene Kim, Jayant Raikhelkar, Takeyohi Ota, Tae Song, Colleen Juricek, Viktoriya Kagan, Valluvan Jeevanandam, Mandeep Mehra, Daniel Burkhoff, and Nir Uriel.
    • From the Department of Medicine (T.I., B.C., A.N., D.R., G.S., S.A., N.S., G.K., J.R., N.U.) and Department of Surgery (T.O., T.S., C.J., V.K., V.J.), University of Chicago Medical Center, IL; Department of Medicine, Brigham and Women's Hospital, Boston, MA (M.M.); and Columbia University Medical Center, Cardiovascular Research Foundation, New York, NY (D.B.).
    • Circ Heart Fail. 2017 Sep 1; 10 (9).

    BackgroundA cohort of heart failure (HF) patients receiving left ventricular assist devices (LVADs) has decoupling of their diastolic pulmonary artery pressure and pulmonary capillary wedge pressure. However, the clinical implications of this decoupling remain unclear.Methods And ResultsIn this prospective study, patients with LVADs underwent routine invasive hemodynamic ramp testing with right heart catheterization, during which LVAD speeds were adjusted. Inappropriate decoupling was defined as a >5 mm Hg difference between diastolic pulmonary artery pressure and pulmonary capillary wedge pressure. The primary outcomes of survival and heart failure readmission rates after ramp testing were assessed. Among 63 LVAD patients (60±12 years old and 25 female [40%]), 27 patients (43%) had inappropriate decoupling at their baseline speed. After adjustment of their rotation speed during ramp testing, 30 patients (48%) had inappropriate decoupling. Uni/multivariable Cox analyses demonstrated that decoupling was the only significant predictor for the composite end point of death and heart failure readmission during the 1 year following the ramp study (total of 18 events; hazards ratio, 1.09; 95% confidence interval, 1.04-1.24; P<0.05). Furthermore, normalization of decoupling (n=8) during ramp testing was significantly associated with higher 1-year heart failure readmission-free survival rate compared with the non-normalized group (n=19, 100% versus 53%; P=0.035).ConclusionsThe presence of inappropriate decoupling was associated with worse outcomes in patients with LVADs. Prospective, large-scale multicenter studies to validate the result are warranted.© 2017 American Heart Association, Inc.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…