-
- Yuhan Ma, Erin L Mazerolle, Junghun Cho, Hongfu Sun, Yi Wang, and G Bruce Pike.
- Department of Biomedical Engineering and McConnell Brain Imaging Centre, McGill University, Montréal, Quebec, Canada.
- Magn Reson Med. 2020 Dec 1; 84 (6): 3271-3285.
PurposeTo use hyperoxia in combination with QSM to quantify microvascular oxygen extraction fraction (OEF) and cerebral metabolic rate of oxygen (CMRO2 ) in healthy subjects and to cross-validate results with those from hypercapnia QSM-OEF.MethodsTen healthy subjects were scanned on a 3T MRI scanner. At baseline normoxia and during hyperoxia (PetO2 = +300 mmHg), QSM data were acquired using a multi-echo gradient-echo (GRE) sequence, and cerebral blood flow data were acquired using a pseudocontinuous arterial spin labeling sequence. The OEF and CMRO2 maps were computed and compared with those from hypercapnia QSM-OEF, acquired in the same subjects, using correlation and Bland-Altman analysis in 16 vascular territories.ResultsHyperoxia QSM-OEF produced physiologically reasonable OEF and CMRO2 values in all subjects (gray-matter region of interest average OEF = 0.42 ± 0.04, average CMRO2 = 181 ± 34 μmol O2 /min/100 g). When compared with hypercapnia QSM-OEF, Bland-Altman plots revealed small deviations (mean OEF difference = 0.015, mean CMRO2 difference = 4.9 μmol O2 /min/100 g, P < .05). Good and excellent correlations of regional OEF and CMRO2 were found for the two methods. In addition, hyperoxia had minimal impact on cerebral blood flow (average gray-matter cerebral blood flow was reduced by 7.5 ± 5.4%).ConclusionsHyperoxia in combination with QSM is a robust approach to measure OEF. Compared with hypercapnia, hyperoxia is more comfortable and has minimal impact on cerebral blood flow.© 2020 International Society for Magnetic Resonance in Medicine.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.