• Magn Reson Med · Jun 2020

    Water-fat Dixon cardiac magnetic resonance fingerprinting.

    • Olivier Jaubert, Gastão Cruz, Aurélien Bustin, Torben Schneider, Begoña Lavin, Peter Koken, Reza Hajhosseiny, Mariya Doneva, Daniel Rueckert, René M Botnar, and Claudia Prieto.
    • School of Biomedical Engineering and Imaging Sciences, King's College London, London, United Kingdom.
    • Magn Reson Med. 2020 Jun 1; 83 (6): 2107-2123.

    PurposeCardiac magnetic resonance fingerprinting (cMRF) has been recently introduced to simultaneously provide T1 , T2 , and M0 maps. Here, we develop a 3-point Dixon-cMRF approach to enable simultaneous water specific T1 , T2 , and M0 mapping of the heart and fat fraction (FF) estimation in a single breath-hold scan.MethodsDixon-cMRF is achieved by combining cMRF with several innovations that were previously introduced for other applications, including a 3-echo GRE acquisition with golden angle radial readout and a high-dimensional low-rank tensor constrained reconstruction to recover the highly undersampled time series images for each echo. Water-fat separation of the Dixon-cMRF time series is performed to allow for water- and fat-specific T1 , T2 , and M0 estimation, whereas FF estimation is extracted from the M0 maps. Dixon-cMRF was evaluated in a standardized T1 -T2 phantom, in a water-fat phantom, and in healthy subjects in comparison to current clinical standards: MOLLI, SASHA, T2 -GRASE, and 6-point Dixon proton density FF (PDFF) mapping.ResultsDixon-cMRF water T1 and T2 maps showed good agreement with reference T1 and T2 mapping techniques (R2 > 0.99 and maximum normalized RMSE ~5%) in a standardized phantom. Good agreement was also observed between Dixon-cMRF FF and reference PDFF (R2 > 0.99) and between Dixon-cMRF water T1 and T2 and water selective T1 and T2 maps (R2 > 0.99) in a water-fat phantom. In vivo Dixon-cMRF water T1 values were in good agreement with MOLLI and water T2 values were slightly underestimated when compared to T2 -GRASE. Average myocardium septal T1 values were 1129 ± 38 ms, 1026 ± 28 ms, and 1045 ± 32 ms for SASHA, MOLLI, and the proposed water Dixon-cMRF. Average T2 values were 51.7 ± 2.2 ms and 42.8 ± 2.6 ms for T2 -GRASE and water Dixon-cMRF, respectively. Dixon-cMRF FF maps showed good agreement with in vivo PDFF measurements (R2 > 0.98) and average FF in the septum was measured at 1.3%.ConclusionThe proposed Dixon-cMRF allows to simultaneously quantify myocardial water T1 , water T2 , and FF in a single breath-hold scan, enabling multi-parametric T1 , T2 , and fat characterization. Moreover, reduced T1 and T2 quantification bias caused by water-fat partial volume was demonstrated in phantom experiments.© 2019 The Authors. Magnetic Resonance in Medicine published by Wiley Periodicals, Inc. on behalf of International Society for Magnetic Resonance in Medicine.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…