- C Trepte, S Haas, N Meyer, M Gebhardt, M S Goepfert, A E Goetz, and D A Reuter.
- Department of Anaesthesiology, Center of Anaesthesiology and Intensive Care Medicine, Cardiovascular Research Center, University Medical Center Hamburg-Eppendorf, Martinistrasse 52, D-20246 Hamburg, Germany.
- Br J Anaesth. 2012 Jun 1; 108 (6): 922-8.
BackgroundCardiac output (CO) monitoring can be useful in high-risk patients during one-lung ventilation (OLV), but it is unclear whether thermodilution-derived CO monitoring is valid during OLV. Therefore, we compared pulmonary artery (CO(PATD)) and transcardiopulmonary thermodilution (CO(TPTD)) with an experimental reference in a porcine model.MethodsCO(PATD) and CO(TPTD) were measured in 23 pigs during double-lung ventilation (DLV) and 15 min after the onset of OLV, during conditions of normovolaemia and after haemorrhage. An ultrasonic flow probe placed around the pulmonary artery (CO(PAFP)) was used for reference.ResultsThe range of CO in these experiments was 1.5-3 litre min(-1). Normovolaemia: during DLV and conditions of normovolaemia, the mean (95% limits of agreement) bias for CO(PATD) compared with CO(PAFP) was -0.05 (-0.92 and 0.83) litre min(-1), and 0.58 (-0.40 and 1.55) litre min(-1) for CO(TPTD). During OLV, the bias for CO(PATD) remained unchanged at 0.08 (-0.51 and 0.66) litre min(-1), P=0.15, and the bias for CO(TPTD) increased significantly to 0.85 (0.05 and 1.64) litre min(-1), P=0.047. Hypovolaemia: during DLV, the bias for CO(PATD) compared with CO(PAFP) was 0.22 (-0.20 and 0.66) litre min(-1) and for CO(TPTD) was 0.60 (0.12 and 1.10) litre min(-1). There was no significant change of bias during OLV for CO(PATD) [0.30 (-0.10 and 0.70) (litre min(-1)), P=0.25] or bias CO(TPTD) [0.72 (0.21 and 1.22) (litre min(-1)), P=0.14]. Trending ability during OLV, quantified by the mean of angles θ, showed good values for both CO(PATD) (θ=11.2°) and CO(TPTD) (θ=1.3°).ConclusionsCO(TPTD) is, to some extent, affected by OLV, whereas CO(PATD) is unchanged. Nonetheless, both methods provide an acceptable estimation of CO and particularly of relative changes of CO during OLV.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.