• Anesthesia and analgesia · Oct 1992

    Comparative Study

    Buccal pulse oximeter is more accurate than finger pulse oximeter in measuring oxygen saturation.

    • R J O'Leary, M Landon, and J L Benumof.
    • Department of Anesthesiology, University of California-San Diego, School of Medicine 92103-8812.
    • Anesth. Analg. 1992 Oct 1;75(4):495-8.

    AbstractAlthough there have been several anecdotal reports of the use of buccal pulse oximeter monitoring (Spo2) when digital Spo2 monitoring cannot be used, there have been no objective evaluations of the accuracy of buccal Spo2 monitoring. The purpose of this study was to systematically compare buccal Spo2 monitoring to both digital Spo2 and arterial O2 saturation monitoring (Sao2) in both generally anesthetized patients in the operating room (n = 31) and critically ill patients in the intensive care unit (n = 23). Buccal Spo2 probes were prepared by taping a malleable metal bar securely over the back of a Nellcor Oxisensor D-25 probe and bending the metal bar and buccal probe firmly around the corner of the patient's mouth. All buccal and finger Spo2 and Sao2 measurements were made simultaneously during hemodynamic stability. We found that buccal Spo2 was higher than finger Spo2 and agreed more closely with Sao2 for both patient groups (98.1% +/- 2.6%, 96.8% +/- 3.5%, 98.5% +/- 2.5%, respectively [mean +/- SD]). The operating room patients had higher buccal and finger Spo2 and Sao2 (99.3% +/- 1.5%, 98.9% +/- 1.4%, 99.5% +/- 0.7%, respectively) than the intensive care unit patients (96.4% +/- 2.9%, 94.1% +/- 3.5%, 96.6% +/- 3.5%, respectively). Although buccal Spo2 monitoring has several disadvantages (i.e., the probe requires preparation, can be more difficult to place, may be less readily accepted in awake patients, and is often mechanically dislodged during airway maneuvers), we conclude that buccal Spo2 monitoring is a more than adequate oximetry alternative when digital Spo2 monitoring is not an option (digits are unavailable or available digits are mechanically interfered with).

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

Want more great medical articles?

Keep up to date with a free trial of metajournal, personalized for your practice.
1,694,794 articles already indexed!

We guarantee your privacy. Your email address will not be shared.