Multicenter Study
Impact of Balloon Guide Catheter Use on Clinical and Angiographic Outcomes in the STRATIS Stroke Thrombectomy Registry.
- Osama O Zaidat, Nils H Mueller-Kronast, Ameer E Hassan, Diogo C Haussen, Ashutosh P Jadhav, Michael T Froehler, Reza Jahan, Ali Aziz-SultanMohammadMBrigham and Women's Hospital, Boston, MA (M.A.A-S.)., Richard P Klucznik, Jeffrey L Saver, Frank R Hellinger, Dileep R Yavagal, Tom L Yao, Rishi Gupta, Coleman O Martin, Hormozd Bozorgchami, Ritesh Kaushal, Raul G Nogueira, Ravi H Gandhi, Eric C Peterson, Shervin Dashti, Curtis A Given, Brijesh P Mehta, Vivek Deshmukh, Sidney Starkman, Italo Linfante, Scott H McPherson, Peter Kvamme, Thomas J Grobelny, Muhammad Shazam Hussain, Ike Thacker, Nirav Vora, Peng Roc Chen, Stephen J Monteith, Robert D Ecker, Clemens M Schirmer, Eric Sauvageau, Alex Bou Chebl, Colin P Derdeyn, Lucian Maidan, Aamir Badruddin, Adnan H Siddiqui, Travis M Dumont, Abdulnasser Alhajeri, Muhammad A Taqi, Khaled Asi, Jeffrey Carpenter, Alan Boulos, Gaurav Jindal, Ajit S Puri, Rohan Chitale, Eric M Deshaies, David Robinson, David F Kallmes, Blaise W Baxter, Mouhammed Jumaa, Peter Sunenshine, Aniel Majjhoo, Joey D English, Shuichi Suzuki, Richard D Fessler, Josser Delgado-Almandoz, Jerry C Martin, David S Liebeskind, and STRATIS Investigators.
- From the Mercy Health St. Vincent Mercy Hospital, Toledo, OH (O.O.Z.).
- Stroke. 2019 Mar 1; 50 (3): 697-704.
AbstractBackground and Purpose- Mechanical thrombectomy has been shown to improve clinical outcomes in patients with acute ischemic stroke. However, the impact of balloon guide catheter (BGC) use is not well established. Methods- STRATIS (Systematic Evaluation of Patients Treated With Neurothrombectomy Devices for Acute Ischemic Stroke) was a prospective, multicenter study of patients with large vessel occlusion treated with the Solitaire stent retriever as first-line therapy. In this study, an independent core laboratory, blinded to the clinical outcomes, reviewed all procedures and angiographic data to classify procedural technique, target clot location, recanalization after each pass, and determine the number of stent retriever passes. The primary clinical end point was functional independence (modified Rankin Scale, 0-2) at 3 months as determined on-site, and the angiographic end point was first-pass effect (FPE) success rate from a single device attempt (modified Thrombolysis in Cerebral Infarction, ≥2c) as determined by a core laboratory. Achieving modified FPE (modified Thrombolysis in Cerebral Infarction, ≥2b) was also assessed. Comparisons of clinical outcomes were made between groups and adjusted for baseline and procedural characteristics. All participating centers received institutional review board approval from their respective institutions. Results- Adjunctive technique groups included BGC (n=445), distal access catheter (n=238), and conventional guide catheter (n=62). The BGC group had a higher rate of FPE following first pass (212/443 [48%]) versus conventional guide catheter (16/62 [26%]; P=0.001) and distal access catheter (83/235 [35%]; P=0.002). Similarly, the BGC group had a higher rate of modified FPE (294/443 [66%]) versus conventional guide catheter (26/62 [42%]; P<0.001) and distal access catheter (129/234 [55%]; P=0.003). The BGC group achieved the highest rate of functional independence (253/415 [61%]) versus conventional guide catheter (23/55 [42%]; P=0.007) and distal access catheter (113/218 [52%]; P=0.027). Final revascularization and mortality rates did not differ across the groups. Conclusions- BGC use was an independent predictor of FPE, modified FPE, and functional independence, suggesting that its routine use may improve the rates of early revascularization success and good clinical outcomes. Clinical Trial Registration- URL: https://www.clinicaltrials.gov . Unique identifier: NCT02239640.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.