- K Nassenstein, K-U Waltering, H Eggebrecht, T Schlosser, P Hunold, and J Barkhausen.
- Abteilung für Diagnostische und Interventionelle Radiologie und Neuroradiologie, Universitätsklinikum Essen. Kai.Nassenstein@uni-essen.de
- Rofo. 2006 May 1; 178 (5): 508-14.
PurposeTo compare the signal-to-noise and contrast-to-noise ratio as well as the image quality of 3D inversion recovery steady-state free precession (IR-SSFP) and 3D inversion recovery fast low angle shot (IR-FLASH) sequences for contrast-enhanced breath-hold MRCA.Materials And Methods24 healthy volunteers (10 female, 14 male, mean age 29.8 +/- 6.1 years) were involved in this study. All examinations were performed on a 1.5 T MR scanner (Magnetom Sonata, Siemens, Germany) after injection of 0.05 mmol/kg body weight MS-325 (EPIX Pharmaceuticals, Cambridge, MA and Schering AG, Berlin, Germany). MRCA was performed using IR-SSFP (TR 3.8 ms, TE 1.6 ms, FA 65 degrees , 35 phase encoded steps, bandwidth 540 Hz/pixel, slice thickness 1.5 mm, in-plane resolution 1.2 x 0.9 - 1.4 x 1.0 mm) and IR-FLASH (TR 3.8 ms, TE 1.6 ms, FA 25 degrees , bandwidth 490 Hz/pixel, slice thickness 1.5 mm, in-plane resolution 1.2 x 0.9 - 1.4 x 1.0 mm) sequences. For all scans the inversion time was set to null the signal intensity of the myocardium. Signal-to-noise ratio (SNR) as well as contrast-to-noise ratio (CNR) measurements (blood versus myocardium) were performed. The image quality was assessed based on a 5-point scale ranging from 1 (excellent) to 5 (non-diagnostic) by two radiologists in consensus.ResultsThe mean signal-to-noise ratio of blood (27.7 +/- 4.7 vs. 22.6 +/- 4.9, P < 0.0001) and the contrast-to-noise ratio (21.0 +/- 4.3 vs. 15.8 +/- 4.3, P < 0.0001) showed significantly higher values for IR-SSFP sequences. The mean image quality scores were significantly higher for SSFP (3.6 +/- 0.7) than FLASH (2.8 +/- 0.9) sequences (P < 0.05).ConclusionIR-SSFP sequences show a considerable overall improvement in image quality compared to IR-FLASH sequences for MRCA after injection of a gadolinium-based blood pool contrast agent.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.