-
Case Reports
Detection of Cerebral Vasospasm Following Aneurysmal Subarachnoid Hemorrhage Using Motor Evoked Potentials.
- Stefan Grossauer, Katharina Koeck, Jakob Kraschl, Oliver Olipitz, Klaus A Hausegger, and Giles H Vince.
- ‡Department of Neurosurgery, General Hospital of Klagenfurt, Klagenfurt, Austria; §Institute of Human Biology, Karl-Franzens University Graz, Graz, Austria; ¶Department of Interventional and Diagnostic Radiology, General Hospital of Klagenfurt, Klagenfurt, Austria.
- Neurosurgery. 2016 Feb 1; 78 (2): 265-73.
BackgroundEarly detection of vasospasm (VS) following aneurysmal subarachnoid hemorrhage (aSAH) is vital to trigger therapy and to prevent infarction and subsequent permanent neurological deficit. Although motor evoked potentials (MEPs) are a well-established method for intraoperative detection of cerebral VS and cerebral ischemia during aneurysm surgery, there are no studies investigating the diagnostic value of MEPs for detecting delayed VS following aSAH in an intensive care unit.ObjectiveA prospective study was conceived to assess the diagnostic accuracy of MEPs in comparison with digital subtraction angiography.MethodsMEP threshold changes were determined in patients both with and without angiographic VS following high-grade aSAHs. Sensitivity, specificity, and the positive and negative predictive values of significant MEP threshold increases, which indicate angiographic VS, were calculated.ResultsIn all patients experiencing VS of the arteries supplying cerebral motor areas, a minimal MEP threshold increase of 50 mA (mean 66.25 mA) was observed, whereas a maximum MEP threshold increase of 30 mA was observed in patients without VS. Therefore, an increase from a baseline of ≥50 mA was considered significant and resulted in a sensitivity of 0.83, a specificity of 0.92, a positive predictive value of 0.83, and a negative predictive value of 0.92.ConclusionVS following aSAH can be detected accurately by using MEPs. MEPs are a feasible bedside tool for online VS detection in an intensive care unit and, therefore, may complement existing diagnostic tools.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.