• Magn Reson Med · Apr 2016

    Variable flip angle T1 mapping in the human brain with reduced T2 sensitivity using fast radiofrequency-spoiled gradient echo imaging.

    • Rahel Heule, Carl Ganter, and Oliver Bieri.
    • Division of Radiological Physics, Department of Radiology, University of Basel Hospital, Basel, Switzerland.
    • Magn Reson Med. 2016 Apr 1; 75 (4): 1413-22.

    PurposeVariable flip angle (VFA) T1 quantification using three-dimensional (3D) radiofrequency (RF) spoiled gradient echo imaging offers the acquisition of whole-brain T1 maps in clinically acceptable times. However, conventional VFA T1 relaxometry is biased by incomplete spoiling (i.e., residual T2 dependency). A new postprocessing approach is proposed to overcome this T2-related bias.MethodsT1 is quantified from the signal ratio of two spoiled gradient echo (SPGR) images acquired at different flip angles using an analytical solution for the RF-spoiled steady-state signal in combination with a global T2 guess. T1 accuracy is evaluated from simulations and in vivo 3D SPGR imaging of the human brain at 3 Tesla.ResultsThe simulations demonstrated that the sensitivity of VFA T1 mapping to T2 can considerably be reduced using a global T2 guess. The method proved to deliver reliable and accurate T1 values in vivo for white and gray matter in good agreement with inversion recovery reference measurements.ConclusionBased on a global T2 estimate, the accuracy of VFA T1 relaxometry in the human brain can substantially be improved compared with conventional approaches which rely on the generally wrong assumption of ideal spoiling.© 2015 Wiley Periodicals, Inc.

      Pubmed     Free full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…