-
- Kelly C McPhee and Alan H Wilman.
- Department of Physics, University of Alberta, Edmonton, Alberta, Canada.
- J Magn Reson Imaging. 2018 Nov 1; 48 (5): 1432-1440.
BackgroundExponential fitting of multiecho spin echo sequences with skipped echoes is still commonly used for quantification of transverse relaxation (T2 ).PurposeTo examine the efficacy of skipped echo methods for T2 quantification against computational modeling of the exact signal decay.Study TypeProspective comparison of methods.Subjects/PhantomEight volunteers were imaged at 4.7T, six volunteers at 1.5T, and phantoms ([MnCl2 ] = 68-270 mM).Field Strength/Sequence1.5T and 4.7T; multiple-echo spin echo.AssessmentExponential fitting for T2 using all echoes, skipping the first echo or skipping all odd echoes, compared with Bloch simulations. Resulting T2 values were examined over a range of T2 (10-150 msec), refocusing flip angles (90-270°), and echo train lengths (ETL = 6-32).Statistical TestsShapiro-Wilk tests and Q-Q plots were used to check for normality of data. Paired sample t-tests and Wilcoxon rank tests were used to compare fitting models using α = 0.05. Multiple comparisons were accounted for with Bonferroni correction.ResultsIn examined regions of interest, typical incorrect estimation of T2 ranged from 23-39% for exponential fitting of all echoes, or 15-32% for skipped echo methods. In vivo, T2 estimation error was reduced to as little as 10% with skipped echo methods using 180° refocusing and ETL = 8, although error varied due to refocusing angle, T2 , and ETL. In vivo, skipped echo T2 values were significantly different than all echo exponential fitting (P < 0.004), but also were significantly different from reference values (P < 0.002, except frontal white matter). Simulations showed skipping the first echo was the most effective form of exponential fitting, in particular for T2 <50 msec and ETL = 8, with potential to reduce T2 errors to 10%, depending on refocusing angle and T2 .Data ConclusionSkipping echoes is insufficient for avoiding stimulated echo contamination. Resulting T2 errors depend on a complicated interplay of T2 , refocusing angle, and ETL. Modeling of the multiecho sequence is recommended.Level Of Evidence2 Technical Efficacy: Stage 1 J. Magn. Reson. Imaging 2018;47:1432-1440.© 2018 International Society for Magnetic Resonance in Medicine.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.