Osteoarthr. Cartil. · Nov 2017
Reliability and measurement error of the Osteoarthritis Research Society International (OARSI) recommended performance-based tests of physical function in people with hip and knee osteoarthritis.
- F Dobson, R S Hinman, M Hall, C J Marshall, T Sayer, C Anderson, N Newcomb, P W Stratford, and K L Bennell.
- Department of Physiotherapy, School of Health Sciences, University of Melbourne, Victoria, Australia. Electronic address: fdobson@unimelb.edu.au.
- Osteoarthr. Cartil. 2017 Nov 1; 25 (11): 1792-1796.
ObjectiveTo estimate the reliability and measurement error of performance-based tests of physical function recommended by the Osteoarthritis Research Society International (OARSI) in people with hip and/or knee osteoarthritis (OA).DesignProspective repeated measures between independent raters within a session and within-rater over a week interval. Relative reliability was estimated for 51 people with hip and/or knee OA (mean age 64.5 years, standard deviation (SD) 6.21 years; 47% females; 36 (70%) primary knee OA) on the 30s Chair Stand Test (30sCST), 40m Fast-Paced Walk Test (40mFPWT), 11-Stair Climb Test (11-step SCT), Timed Up and Go (TUG), Six-Minute Walk Test (6MWT), 10m Fast-Paced Walk Test (10mFPWT) and 20s Stair Climb Test (20sSCT) using intra-class correlation coefficients (ICC). Absolute reliability was calculated using standard error of measurement (SEM) and minimal detectable change (MDC).ResultsMeasurement error was acceptable (SEM < 10%) for all tests. Between-rater reliability was: optimal (ICC > 0.9, lower 1-sided 95% CI > 0.7) for the 40mFPWT, 6MWT and 10mFPWT; sufficient (ICC >0.8, lower 1-sided 95% CI > 0.7) for 30sCST, 20sSCT; unacceptable (lower 1-side 95% CI < 0.7) for 11-step SCT and TUG. Within-rater reliability was optimal for 40mFPWT, and 6MWT; sufficient for 30sCST and 10mFPWT and unacceptable for 11-step SCT, TUG and 20sSCT.ConclusionsThe 30sCST, 40mFPWT, 6MWT and 10mFPWT, demonstrated, at minimum, acceptable levels of both between and within-rater reliability and measurement error. All tests demonstrated sufficiently small measurement error indicating they are adequate for measuring change over time in individuals with knee/hip OA.Copyright © 2017 Osteoarthritis Research Society International. All rights reserved.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.