-
- Thomas E Yankeelov, William D Rooney, Xin Li, and Charles S Springer.
- Chemistry Department, Brookhaven National Laboratory, Upton, New York, USA.
- Magn Reson Med. 2003 Dec 1; 50 (6): 1151-69.
AbstractContrast reagents (CRs) may enter the tissue interstitium for a period after a vascular bolus injection. As the amount of interstitial CR increases, the longitudinal relaxographic NMR "shutter-speed" (T(-1)) for the equilibrium transcytolemmal water exchange process increases. The quantity T(-1) is given by |r(1o)[CR(o)] + R(1o0) - R(1i)| (where r(1o) and [CR(o)] represent the interstitial (extracellular) CR relaxivity and concentration, respectively, and R(1o0) and R(1i) are the extra- and intracellular (1)H(2)O relaxation rate constants, respectively, in the absence of exchange). The increase of T(-1) with [CR(o)] causes the kinetics of the water exchange equilibrium to appear to decrease. Here, analytical theory for two-site-exchange processes is combined with that for pharmacokinetic CR delivery, extraction, and distribution in a method termed BOLus Enhanced Relaxation Overview (BOLERO(Copyright )). The shutter-speed effect alters the shape of the bolus-tracking (B-T) time-course. It is shown that this is mostly accounted for by the inclusion of only one additional parameter, which measures the mean intracellular lifetime of a water molecule. Simulated and real data demonstrate that the effect of shutter-speed variation on pharmacokinetic parameters can be very significant: neglecting this effect can lead to an underestimation of the parameter values by 50%. This phenomenon can be heterogeneous. Within a tiny gliosarcoma implanted in the rat brain, the interstitial CR in the tumor core never rises to a level sufficient to cause apparent slowing of the exchange process. However, within the few microns needed to reach the proliferating rim, this occurs to a significant degree. Thus, even relative pharmacokinetic quantities can be incorrectly represented in a parametric map that neglects this effect. The BOLERO analysis shows promise for in vivo vascular phenotyping in pathophysiology. It also includes a provision for approximating the separation of the perfusion and permeability contributions to CR extravasation.Copyright 2003 Wiley-Liss, Inc.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.