-
J. Cardiovasc. Electrophysiol. · May 2019
Long-term efficacy and safety of radiofrequency catheter ablation of atrial fibrillation in patients with cardiac implantable electronic devices and transvenous leads.
- Leon Dinshaw, Benjamin Schäffer, Özge Akbulak, Mario Jularic, Jens Hartmann, Niklas Klatt, Jannis Dickow, Melanie Gunawardene, Paula Münkler, Samer Hakmi, Simon Pecha, Arian Sultan, Jakob Lüker, Hans Pinnschmidt, Boris Hoffmann, Nils Gosau, Christian Eickholt, Stephan Willems, Daniel Steven, and Christian Meyer.
- Department of Cardiology-Electrophysiology, University Hospital Hamburg, University Heart Center Hamburg, Hamburg, Germany.
- J. Cardiovasc. Electrophysiol. 2019 May 1; 30 (5): 679-687.
IntroductionLong-term efficacy and safety are uncertain in patients with cardiac implantable electronic devices (CIED) and transvenous leads (TVL) undergoing radiofrequency catheter ablation of atrial fibrillation (AF). Thus, we assessed the outcome of AF ablation in those patients during long-term follow-up using continuous atrial rhythm monitoring (CARM).Methods And ResultsA total of 190 patients (71.3 ± 10.7 years; 108 (56.8% men) were included in this study. At index procedure 81 (42.6%) patients presented with paroxysmal AF and 109 (57.4%) with persistent AF. The ablation strategy included pulmonary vein isolation in all patients and biatrial ablation of complex fractionated electrograms with additional ablation lines, if appropriate. AF recurrences were assessed by CARM- and CIED-related complications by device follow-up. After a mean follow-up of 55.4 ± 38.1 months, freedom of AF was found in 86 (61.4%) and clinical success defined as an AF burden less than or equal to 1% in 101 (72.1%) patients. Freedom of AF was reported in 74.6% and 51.9% (P = 0.006) and clinical success in 89.8% and 59.3% (P < 0.001) of patients with paroxysmal and persistent AF, respectively. In 3 of 408 (0.7%) ablation procedures, a TVL malfunction occurred within 90 days after catheter ablation. During long-term follow-up 9 (4.7%) patients showed lead dislodgement, 2 (1.1%) lead fracture, and 2 (1.1%) lead insulation defect not related to the ablation procedure.ConclusionOur findings using CARM demonstrate long-term efficacy and safety of radiofrequency catheter ablation of AF in patients with CIED and TVL.© 2019 Wiley Periodicals, Inc.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.