• J Magn Reson Imaging · Feb 2015

    Comparative Study

    MR-guided sclerotherapy of low-flow vascular malformations using T2 -weighted interrupted bSSFP (T2 W-iSSFP): comparison of pulse sequences for visualization and needle guidance.

    • Di Xu, Daniel A Herzka, Wesley D Gilson, Elliot R McVeigh, Jonathan S Lewin, and Clifford R Weiss.
    • Department of Biomedical Engineering, Johns Hopkins University School of Medicine, Baltimore, Maryland, USA.
    • J Magn Reson Imaging. 2015 Feb 1; 41 (2): 525-35.

    PurposeImage-guided treatment of low-flow vascular (venous or lymphatic) malformations presents a challenging visualization problem, regardless of the imaging modality being used for guidance. The purpose of this study was to employ a new magnetic resonance imaging (MRI) sequence, T2 -weighted interrupted balanced steady-state free precession (T2 W-iSSFP), for real-time image guidance of needle insertion.Materials And MethodsT2 W-iSSFP uses variable flip angle balanced steady-state free precession (bSSFP, a.k.a. SSFP) to establish T2 -weighting and fat suppression. Swine (n = 3) and patients (n = 4, three female, all with venous malformations) were enrolled in the assessment. T2 -weighted turbo spin echo (T2 -TSE) with spectral adiabatic inversion recovery (SPAIR), SPAIR-T2 -TSE or T2 -TSE for short, was used as the reference. T2 -weighted half Fourier acquired single shot turbo spin echo (T2 -HASTE) with SPAIR (SPAIR-T2 -HASTE, T2 -HASTE for short), fat saturated bSSFP (FS-SSFP), and T2 W-iSSFP were imaged. Numeric metrics, namely, contrast-to-noise ratio (CNR) efficiency (CNR divided by the square root of acquisition time) and local sharpness (the reciprocal of edge width), were used to assess image quality. MR-guided sclerotherapy was performed on the same patients using real-time T2 W-iSSFP to guide needle insertion.ResultsComparing the visualization of needles in the images of swine, the local sharpness (mm(-1) ) was: 0.21 ± 0.06 (T2 -HASTE), 0.48 ± 0.02 (FS-SSFP), and 0.49 ± 0.03 (T2 W-iSSFP). T2 W-iSSFP is higher than T2 -HASTE (P < 0.001). For the patient images, their CNR efficiencies were: 797 ± 66 (T2 -HASTE), 281 ± 44 (FS-SSFP), and 860 ± 29 (T2 W-iSSFP). T2 W-iSSFP is higher than FS-SSFP (P < 0.02). The frame rate of T2 W-iSSFP was 2.5-3.5 frames per second. All MR-guided sclerotherapy procedures were successful, with all needles (six punctures) placed in the targets.ConclusionT2 W-iSSFP provides effective lesion identification and needle visualization. This new pulse sequence can be used for MR-guided sclerotherapy of low-flow vascular malformations. It may have potential use in other MR-guided procedures where heavily T2 -weighted real-time images are needed.© 2014 Wiley Periodicals, Inc.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…