• J Thorac Dis · Jun 2014

    Nocturnal pulse rate and symptomatic response in patients with obstructive sleep apnoea treated with continuous positive airway pressure for one year.

    • Martino F Pengo, Panagis Drakatos, Christopher Kosky, Adrian Williams, Nicholas Hart, Gian Paolo Rossi, and Joerg Steier.
    • 1 Guy's and St. Thomas' NHS Foundation Trust, Lane Fox Respiratory Unit/Sleep Disorders Centre, London, UK ; 2 Department of Medicine (DIMED), University of Padua, Italy ; 3 University Hospital of Patras, ... more Rio, Patras, Greece ; 4 King's Health Partners, London, UK ; 5 King's College London School of Medicine, UK ; 6 NIHR Comprehensive Biomedical Research Centre, Guy's & St Thomas' NHS Foundation Trust and King's College London, London, UK. less
    • J Thorac Dis. 2014 Jun 1; 6 (6): 598-605.

    BackgroundObstructive sleep apnoea (OSA) is the most common form of sleep-disordered breathing and a known risk factor for cardiovascular disease. We hypothesised that in patients with OSA the characteristics of nocturnal pulse rate (PR) are associated with changes in blood pressure and daytime sleepiness, following commencement of continuous positive airway pressure (CPAP) therapy.MethodsPulse oximetry data, demographics, daytime sleepiness and blood pressure were recorded at baseline and at one year follow up. Patients with OSA were grouped according to positive and negative changes in the PR (ΔPR) response during the first night of pulse oximetry before commencement of CPAP.ResultsA total of 115 patients (58 with OSA and 57 matched subjects without OSA) were identified and included in the analysis. The scale of improvement in daytime sleepiness could be predicted by a negative or positive ΔPR, as recorded in the initial screening pulse oximetry [ΔESS -5.8 (5.1) vs. -0.8 (7.2) points, P<0.05]. A negative correlation was observed between mean nocturnal PR and changes in systolic blood pressure (SBP) after one year of CPAP treatment (r=-0.42, P<0.05).ConclusionsMean nocturnal PR prior to CPAP initiation was associated with changes in SBP at one year follow up. A descending nocturnal PR in patients with OSA, prior to CPAP initiation, might help to identify a symptomatic response from long term CPAP treatment.

      Pubmed     Free full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        

    hide…

What will the 'Medical Journal of You' look like?

Start your free 21 day trial now.

We guarantee your privacy. Your email address will not be shared.