• Br J Anaesth · Sep 2012

    Detection of hypotension during Caesarean section with continuous non-invasive arterial pressure device or intermittent oscillometric arterial pressure measurement.

    • C Ilies, B Bein, M Steinfath, R Hanss, P Meybohm, H Kiskalt, and D Siedenhans.
    • Department of Anaesthesiology and Intensive Care Medicine, University Hospital Schleswig-Holstein, Campus Kiel, Schwanenweg 21, 24105 Kiel, Germany. ilies@anaesthesie.uni-kiel.de
    • Br J Anaesth. 2012 Sep 1;109(3):413-9.

    BackgroundThe intensified use of spinal anaesthesia (SPA) for Caesarean section significantly contributed to a decreased maternal mortality and morbidity. Nevertheless, one of the major side-effects is hypotension after SPA with potential negative effects on the fetus. Owing to discontinuous oscillometric measurements (non-invasive arterial pressure, NIAP), hypotensive episodes may be missed. Recently, a continuous NIAP measurement device (CNAP) with acceptable agreement with the mean invasive AP was introduced. We hypothesized that CNAP detects hypotensive episodes more reliably compared with NIAP measurements.MethodsA total of 65 women undergoing Caesarean section under SPA were included in the study analysis. A total of 888 NIAP measurements obtained at 3 min cycles, starting from before SPA and continued until delivery, were analysed.ResultsWhen averaged over all cycles, the lowest systolic AP identified by CNAP in each cycle [105 mm Hg, (24.4)] was significantly lower (P<0.001) than the average of the individual corresponding single NIAP measurements [126 mm Hg (22.1)] and highest CNAP average [126 mm Hg (24.5)]. Hypotension (systolic AP <100 mm Hg) was detected in 39% of all cycles with CNAP and in 9% with NIAP. Hypotension was detected in 91% of the patients based on CNAP and in 55% based on NIAP. Fetal acidosis defined by an umbilical vein pH under 7.25 did not occur when the lowest systolic AP measured by CNAP was above 100 mm Hg.ConclusionsThe CNAP device detected more hypotensive episodes after SPA and significantly lower AP compared with NIAP. AP monitoring based on CNAP may improve haemodynamic management in this patient population with potential benefit for the fetus.

      Pubmed     Free full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

What will the 'Medical Journal of You' look like?

Start your free 21 day trial now.

We guarantee your privacy. Your email address will not be shared.