-
- Leon M Ptaszek, Paul J Wang, Sharon A Hunt, Hannah Valantine, Mark Perlroth, and Amin Al-Ahmad.
- Department of Internal Medicine, Stanford University School of Medicine, Stanford, California 94305, USA.
- Heart Rhythm. 2005 Sep 1; 2 (9): 931-3.
BackgroundOrthotopic heart transplantation is considered an effective treatment for patients with refractory heart failure. The long-term survival of orthotopic heart transplantation recipients has increased over the last several decades, but many long-term survivors of orthotopic heart transplantation develop graft atherosclerosis and associated left ventricular dysfunction. The risk of sudden cardiac death in long-term survivors of orthotopic heart transplantation with these complications is believed to be high. There are no data on the usefulness of implantable cardioverter-defibrillators (ICDs) in this population; therefore, we report our early experience with ICD placement in such patients.ObjectivesThe purpose of this study was to examine the use of ICDs in adults who are long-term survivors of heart transplantation.MethodsWe retrospectively reviewed all adult patients who underwent orthotopic heart transplantation at Stanford University Hospital (Stanford, CA, USA) from 1980 to 2004. All patients who received an ICD after transplant were included in this study. We reviewed demographic data, medical history, ejection fraction, presence of graft atherosclerosis, indication for ICD placement, and any device therapy delivered.ResultsOf the 925 patients who had orthotopic heart transplantation during this time period, 493 patients were alive at the beginning of the year 2000. Of these patients, 10 ( approximately 2%) had subsequent placement of an ICD. All 10 patients were male. The average age at orthotopic heart transplantation was 37.8 years. The average age at ICD placement was 50.5 years. The average time from orthotopic heart transplantation to ICD placement was 14.6 years. The average ejection fraction at the time of implant was 46.5%. Five of the 10 patients had a low ejection fraction (within this subgroup, the average ejection fraction was 31%, range 15%-45%) and graft atherosclerosis. ICDs were placed because of symptomatic episodes of ventricular tachycardia (3 patients), low ejection fraction and severe graft atherosclerosis without symptoms (3 patients), and after thorough evaluation for otherwise unexplained syncope (4 patients). The average follow-up after device implantation was 13 months. Complications related to ICD placement were an infected ICD system requiring explant in one patient and a lead fracture in another patient. Three patients had subsequent appropriate shocks for ventricular arrhythmias, and one patient underwent a second orthotopic heart transplantation. One patient died of malignancy.ConclusionUse of the ICD in long-term survivors of orthotopic heart transplantation should be considered in appropriately selected patients. Further data are needed regarding ICD use in this population.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.