• J. Nucl. Med. · Apr 2003

    Comparative Study Clinical Trial

    Left ventricular ejection fraction and volumes from gated blood-pool SPECT: comparison with planar gated blood-pool imaging and assessment of repeatability in patients with heart failure.

    • Graham A Wright, Simon Thackray, Syd Howey, and John G Cleland.
    • Department of Nuclear Medicine, Hull Royal Infirmary, Anlaby Road, Kingston Upon Hull, UK. graham@physicist.net
    • J. Nucl. Med. 2003 Apr 1; 44 (4): 494-8.

    UnlabelledGated blood-pool SPECT (GBPS) has several potential advantages over planar radionuclide ventriculography (PRNV), including the possibility of greater repeatability of left ventricular ejection fraction (LVEF) and the noninvasive calculation of left ventricular end-systolic volume and left ventricular end-diastolic volume (LVEDV). The aim of this study was to assess the repeatability of LVEF and LVEDV from GBPS and to compare LVEF with those from PRNV.MethodsFifty patients underwent PRNV and GBPS, 23 of whom also had repeated studies in the same session. GPBS studies were processed using the Cedars Sinai Quantitative Blood-Pool SPECT (QBS) software that automatically calculates LVEF and LVEDV. Automatic processing with QBS was successful in 70% of the GBPS studies, with the remaining studies processed using the manual option in QBS. All PRNV studies were processed using a manual processing technique.ResultsComparison of LVEF from PRNV and GBPS yielded a correlation coefficient of 0.80. Bland-Altman analysis demonstrated a mean difference of 0.74% +/- 7.62% (mean +/- SD) between LVEF from the 2 techniques. The 95% limits of agreement are therefore -14.50% to +15.98%. The correlation between repeated measurements was 0.87 for GBPS and 0.95 for PRNV. Bland-Altman analysis revealed poorer repeatability for GBPS (95% limits of agreement, -9.63% to +14.97% vs. -4.66% to +5.92%; P = 0.003). The mean LVEDV was 198 +/- 94 mL, with a mean difference of 9 +/- 47 mL between repeated measurements. The 95% limits of agreement are therefore -85 to +103 mL.ConclusionGBPS provides a less repeatable measurement of LVEF than PRNV. Repeatability of LVEDV measurements from GBPS is poor.

      Pubmed     Free full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…