• Anesthesiology · Dec 2015

    Fiber-optic Monitoring of Spinal Cord Hemodynamics in Experimental Aortic Occlusion.

    • Angela S Kogler, Thomas V Bilfinger, Robert M Galler, Rickson C Mesquita, Michael Cutrone, Steven S Schenkel, Arjun G Yodh, and Thomas F Floyd.
    • From the Departments of Anesthesiology (A.S.K., M.C., T.F.F.), Surgery (T.V.B.), and Neurological Surgery (R.M.G.), Stony Brook University Medical Center, Stony Brook, New York; Department of Biomedical Engineering, Stony Brook University, Stony Brook, New York (A.S.K., T.F.F.); Department of Physics and Astronomy, University of Pennsylvania, Philadelphia, Pennsylvania (R.C.M., S.S.S., A.G.Y.); and Institute of Physics, University of Campinas, Campinas, São Paulo, Brazil (R.C.M.).
    • Anesthesiology. 2015 Dec 1; 123 (6): 136213731362-73.

    BackgroundSpinal cord ischemia occurs frequently during thoracic aneurysm repair. Current methods based on electrophysiology techniques to detect ischemia are indirect, non-specific, and temporally slow. In this article, the authors report the testing of a spinal cord blood flow and oxygenation monitor, based on diffuse correlation and optical spectroscopies, during aortic occlusion in a sheep model.MethodsTesting was carried out in 16 Dorset sheep. Sensitivity in detecting spinal cord blood flow and oxygenation changes during aortic occlusion, pharmacologically induced hypotension and hypertension, and physiologically induced hypoxia/hypercarbia was assessed. Accuracy of the diffuse correlation spectroscopy measurements was determined via comparison with microsphere blood flow measurements. Precision was assessed through repeated measurements in response to pharmacologic interventions.ResultsThe fiber-optic probe can be placed percutaneously and is capable of continuously measuring spinal cord blood flow and oxygenation preoperatively, intraoperatively, and postoperatively. The device is sensitive to spinal cord blood flow and oxygenation changes associated with aortic occlusion, immediately detecting a decrease in blood flow (-65 ± 32%; n = 32) and blood oxygenation (-17 ± 13%, n = 11) in 100% of trials. Comparison of spinal cord blood flow measurements by the device with microsphere measurements led to a correlation of R = 0.49, P < 0.01, and the within-sheep coefficient of variation was 9.69%. Finally, diffuse correlation spectroscopy is temporally more sensitive to ischemic interventions than motor-evoked potentials.ConclusionThe first-generation spinal fiber-optic monitoring device offers a novel and potentially important step forward in the monitoring of spinal cord ischemia.

      Pubmed     Free full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…