• Cochrane Db Syst Rev · Oct 2014

    Review Meta Analysis

    Capsule endoscopy for the diagnosis of oesophageal varices in people with chronic liver disease or portal vein thrombosis.

    • Agostino Colli, Juan Cristóbal Gana, Dan Turner, Jason Yap, Thomasin Adams-Webber, Simon C Ling, and Giovanni Casazza.
    • Department of Internal Medicine, Ospedale "A Manzoni" Lecco, Via dell'Eremo, 9/11, Lecco, Italy, 23900.
    • Cochrane Db Syst Rev. 2014 Oct 1 (10): CD008760.

    BackgroundCurrent guidelines recommend performance of oesophago-gastro-duodenoscopy at the time of diagnosis of hepatic cirrhosis to screen for oesophageal varices. These guidelines require people to undergo an unpleasant invasive procedure repeatedly with its attendant risks, despite the fact that half of the people do not have identifiable oesophageal varices 10 years after the initial diagnosis of cirrhosis. Video capsule endoscopy is a non-invasive test proposed as an alternative method for the diagnosis of oesophageal varices.ObjectivesTo determine the diagnostic accuracy of capsule endoscopy for the diagnosis of oesophageal varices in children or adults with chronic liver disease or portal vein thrombosis, irrespective of the aetiology. To investigate the accuracy of capsule endoscopy as triage or replacement of oesophago-gastro-duodenoscopy.Search MethodsWe searched the Cochrane Hepato-Biliary Group Diagnostic Test Accuracy Studies Register (October 2013), MEDLINE (Ovid SP) (1950 to October 2013), EMBASE (Ovid SP) (1980 to October 2013), ACP Journal Club (Ovid SP) (1991 to October 2013), Database of Abstracts of Reviews of Effects (DARE) (Ovid SP) (third quarter), Health Technology Assessment (HTA) (Ovid SP) (third quarter), NHS Economic Evaluation Database (NHSEED) (Ovid SP) (third quarter), and Science Citation Index Expanded (SCI-EXPANDED) (ISI Web of Knowledge) (1955 to October 2013). We applied no language or document type restrictions.Selection CriteriaStudies that evaluated the diagnostic accuracy of capsule endoscopy for the diagnosis of oesophageal varices using oesophago-gastro-duodenoscopy as the reference standard in children or adults of any age, with chronic liver disease or portal vein thrombosis.Data Collection And AnalysisWe followed the available guidelines provided in the Cochrane Handbook for Diagnostic Test of Accuracy Reviews. We calculated the pooled estimates of sensitivity and specificity using the bivariate model due to the absence of a negative correlation in the receiver operating characteristic (ROC) space and of a threshold effect.Main ResultsThe search identified 16 eligible studies, in which only adults with cirrhosis were included. In one study, people with portal thrombosis were also included. We classified most of the studies at high risk of bias for the 'Participants selection' and the 'Flow and timing' domains. One study assessed the accuracy of capsule endoscopy for the diagnosis of large (high-risk) oesophageal varices. In the remaining15 studies that assessed the accuracy of capsule endoscopy for the diagnosis of oesophageal varices of any size in people with cirrhosis, 936 participants were included; the pooled estimate of sensitivity was 84.8% (95% confidence interval (CI) 77.3% to 90.2%) and of specificity 84.3% (95% CI 73.1% to 91.4%). Eight of these studies included people with suspected varices or people with already diagnosed or even treated varices, or both, introducing a selection bias. Seven studies including only people with suspected but unknown varices were at low risk of bias; the pooled estimate of sensitivity was 79.7% (95% CI 73.1% to 85.0%) and of specificity 86.1% (95% CI 64.5% to 95.5%). Six studies assessed the diagnostic accuracy of capsule endoscopy for the diagnosis of large oesophageal varices, associated with a higher risk of bleeding; the pooled sensitivity was 73.7% (95% CI 52.4% to 87.7%) and of specificity 90.5% (95% CI 84.1% to 94.4%). Two studies also evaluated the presence of red marks, which are another marker of high risk of bleeding; the estimates of sensitivity and specificity varied widely. Two studies obtained similar results with the use of a modified device as index test (string capsule). Due to the absence of data, we could not perform all planned subgroup analyses. Interobserver agreement in the interpretation of capsule endoscopy results and any adverse event attributable to capsule endoscopy were poorly assessed and reported. Only four studies evaluated the interobserver agreement in the interpretation of capsule endoscopy results: the concordance was moderate. The participants' preferences for capsule endoscopy or oesophago-gastro-duodenoscopy were reported differently but seemed in favour of capsule endoscopy in nine of 10 studies. In 10 studies, participants reported some minor discomfort on swallowing the capsule. Only one study identified other significant adverse events, including impaction of the capsule due to previously unidentified oesophageal strictures in two participants. No adverse events were reported as a consequence of the reference standard.Authors' ConclusionsWe cannot support the use of capsule endoscopy as a triage test in adults with cirrhosis, administered before oesophago-gastro-duodenoscopy, despite the low incidence of adverse events and participant reports of being better tolerated. Thus, we cannot conclude that oesophago-gastro-duodenoscopy can be replaced by capsule endoscopy for the detection of oesophageal varices in adults with cirrhosis. We found no data assessing capsule endoscopy in children and in people with portal thrombosis.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…