• Radiology · Dec 2004

    Catheter visualization with resonant markers at MR imaging-guided deployment of endovascular stents in swine.

    • Titus Kuehne, Steffen Weiss, Florian Brinkert, Jochen Weil, Sevim Yilmaz, Boris Schmitt, Peter Ewert, Peter Lange, and Matthias Gutberlet.
    • Departments of Congenital Heart Disease and Pediatric Cardiology, German Heart Institute, Augustenburger Platz 1, Berlin 13037, Germany. titus.kuehne@dhzb.de
    • Radiology. 2004 Dec 1; 233 (3): 774-80.

    PurposeTo evaluate resonant circuits as markers for magnetic resonance (MR) imaging-guided placement of nitinol stents.Materials And MethodsThe study was approved by the institutional animal research committee and complied with National Institutes of Health guidelines for care and use of laboratory animals. Resonant circuits similar to catheter markers used at conventional angiography were placed proximally and distally to a nitinol stent in a stent delivery system. Resonant circuits were tested in vitro and in vivo for signal intensity levels that would enable visualization during MR imaging-guided stent deployment. Experiments were conducted by using real-time imaging with a 1.5-T unit. Stents (n = 9) were deployed in the vena cava (n = 2), abdominal aorta (n = 2), isthmus of the aorta (n = 2), and carotid (n = 2) and iliac (n = 1) arteries in five pigs. After intervention, the site of the stent was investigated with balanced fast field-echo MR imaging and contrast material-enhanced MR angiography. Blood flow velocities were measured in the stent lumen and next to the stent with velocity-encoded cine MR imaging. Level of agreement was determined with Bland-Altman analysis.ResultsDuring all interventions, resonant circuits provided highly visible MR signal that allowed fast and reliable visualization of the stent delivery system. Borders of loaded stents were clearly marked, which allowed precise stent placement in all experiments. Balanced fast field-echo MR imaging and contrast-enhanced MR angiography provided information about immediate postintervention position. Positions depicted on MR images were found accurate at postmortem examination. Results of Bland-Altman analysis showed good agreement between blood flow velocities measured in and next to the stent lumen, with a mean difference of -9 cm/sec +/- 5 (standard deviation).ConclusionResonant circuits are well suited for use at deployment of endovascular stents.(c) RSNA, 2004.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…