-
J Clin Monit Comput · Aug 2022
Randomized Controlled TrialComparing the first-attempt tracheal intubation success of the hyperangulated McGrath® X-blade vs the Macintosh-type CMAC videolaryngoscope in patients with cervical immobilization: a two-centre randomized controlled trial.
- Jinbin Zhang, Leng Zoo Tan, Han Toh, Chek Wun Foo, Sujani Wijeratne, Hilda Hu, and Edwin Seet.
- Tan Tock Seng Hospital, 11 Jalan Tan Tock Seng, Singapore, 308433, Singapore. Jinbin_zhang@ttsh.com.sg.
- J Clin Monit Comput. 2022 Aug 1; 36 (4): 1139-1145.
AbstractWe compared the hyperangulated McGrath X-blade with the Macintosh-type CMAC videolaryngoscope through the use of manual in-line stabilization on patients. The primary hypothesis was that the McGrath X-blade has a similar first-attempt success rate as the CMAC videolaryngoscope. 210 patients of ASA physical status I to III, aged 21 to 80 years old, undergoing general anesthesia requiring tracheal intubation were prospectively recruited into this two-centre randomized controlled trial, from June 2016 to April 2019. Patients with history of or predicted difficult airway, pre-existing dental risks, BMI > 35 kg/m2, cervical spondylosis or myelopathy, aspiration risks, patients who declined to participate or lacked the mental capacity to give consent were excluded. Participants were intubated using either hyperangulated McGrath X-blade (MGX) or Macintosh-type CMAC (CM) videolaryngoscopy, with manual in-line stabilization. Primary outcome measured was first-attempt tracheal intubation success. Secondary outcomes included overall successful intubation within 2 attempts or 120 s, time to intubation, glottic view obtained and intubation-related complications. First-attempt success rates were 71.4% in the MGX group vs. 79.0% in the CM group (p = 0.26), with an absolute difference of -7.6% (95%CI -20%, 5.0%, p value = 0.26), but this trial was underpowered to detect a difference. Overall success was 91.4% (MGX) vs. 92.4% (CM) (p > 0.99). The Cormack & Lehane laryngeal grade was superior in the MGX group compared to CM group (Grade I: MGX 44%, CM 23%; Grade II: MGX 53%, CM 45%; Grade III: MGX 3%, CM 32%; p < 0.001). The median time to intubation using the MGX was longer than the CM [MGX 55.5 s (42.1-78.3), CM 43.8 s (38-55.3); p < 0.001]. Our study did not demonstrate a significant difference in efficacy between the McGrath X-blade and the CMAC videolaryngoscope. In patients with manual in-line stabilization, no anticipated airway difficulty and in the hands of experienced operators, the McGrath X-blade provided superior glottic views but conferred no advantage over the C-MAC, with a longer median time to intubation compared to the CMAC videolaryngoscope.Trial registration: Australian New Zealand Clinical Trial Registry (ACTRN12616000668404).© 2021. The Author(s), under exclusive licence to Springer Nature B.V.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.