• Int Orthop · Feb 2014

    Randomized Controlled Trial

    Improved kinematics of total knee replacement following partially navigated modified gap-balancing technique.

    • Clemens Baier, Wolfgang Fitz, Ben Craiovan, Armin Keshmiri, Sebastian Winkler, Robert Springorum, Joachim Grifka, and Johannes Beckmann.
    • Orthopaedic Surgery, University of Regensburg, Regensburg, Germany, c.baier@asklepios.com.
    • Int Orthop. 2014 Feb 1; 38 (2): 243-9.

    PurposeNavigation-based total knee arthroplasty (TKA) has proven its value for restoration of the limb axis. However, patient-orientated results after TKA show a wide variation from the correct implantation technique. Nonphysiological kinematics without posterior femoral rollback and tibial internal rotation in flexion could be one reason for this. We postulated that a modified gap-balancing technique with navigation of the tibia alone, in comparison to a conventional navigated technique, would: (1) obtain lateral femoral rollback, (2) alter condylar liftoff without midflexion instability, (3) significantly differ in femoral and tibial cuts, (4) not be inferior in leg-axis restoration and (5) be comparable in clinical short-term scores.MethodsIn this prospective study, we compared in vivo navigation-based kinematics pre- and postoperatively of 40 consecutive TKA comprising 21 conventional navigation-based TKA and 19 TKA with the modified gap-balancing technique and a reduced navigation workflow. All cuts were double checked and compared with cuts proposed by the navigation system. Clinical results were assessed preoperatively and six months postoperatively.ResultsThe modified gap-balancing technique resulted in significantly increased lateral femoral rollback (mean 16.3 mm) and lateral condylar liftoff (mean 1.3 mm) compared to the conventional group. The modified technique comprised an average of 2.1 mm less distal femoral resection and an average of 4° less external rotation and 3.5° more flexion of the femoral component compared with the control group. Average tibial resection height was 1.1 mm greater and average tibial slope was 0.5° elevated compared to the control group. A neutral leg axis was achieved in all cases. Results showed no significant differences in clinical scores between groups.ConclusionA partial navigation solely of the tibial cut can securely restore the leg axis. Modification of the surgical technique can possibly reproduce more physiological knee kinematics with higher lateral femoral rollback in flexion without midflexion instability. This might help reduce postoperative problems with the new implant and thus reduce the amount of unsatisfactory results. Despite equal short-term results, mid- to long-term results are needed to prove whether or not this correlates with better clinical results and at least equal implant longevity.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

What will the 'Medical Journal of You' look like?

Start your free 21 day trial now.

We guarantee your privacy. Your email address will not be shared.