• Journal of neurosurgery · Feb 2022

    Endovascular catheter manometry reliability: a benchtop validation study.

    • Daniel M Heiferman, Linh N Le, David Klinger, and Joseph C Serrone.
    • 1Semmes-Murphey Clinic, Department of Neurological Surgery, Memphis, Tennessee.
    • J. Neurosurg. 2022 Feb 1; 136 (2): 485491485-491.

    ObjectiveCatheter manometry is used frequently in neuroendovascular surgery for assessing cerebrovascular pathology. The accuracy of pressure data with different catheter setups requires further validation.MethodsIn a silicone human vascular model with a pulsatile pump, pressure measurements were taken through multiple arrangements of 2 guide catheters and 6 microcatheters. The systolic pressure, diastolic pressure, mean pressure, pulse pressure, and area under the curve of the waveform were recorded through catheters with controls at arterial blood pressure ranges. Linear regression modeling was performed, correlating transduction area and relative pulse pressure. Thresholds for acceptable accuracy were ≥ 90%.ResultsMean pressure demonstrated < 4% variation between all 24 catheter setups and respective controls. A strong linear correlation (r2 = 0.843, p < 0.0005) between microcatheter transduction area and relative pulse pressure with a threshold of 0.50 mm2 was seen (i.e., 0.031-inch inner diameter [ID]). For guide catheters with indwelling microcatheters, there was also a strong linear correlation (r2 = 0.840, p < 0.0005) of transduction area to pulse pressure. The guide catheters with obstructing microcatheters required a transduction area over fourfold higher compared with unobstructed microcatheters (2.21 mm2 vs 0.50 mm2).ConclusionsMean pressure measurements are accurate through microcatheters as small as 0.013-inch ID. Pulse pressure and waveform morphology may require a microcatheter ≥ 0.031-inch ID to achieve 90% accuracy, although the 0.027-inch ID microcatheter reached 85% accuracy. A 0.070-inch guide catheter with a microcatheter ≤ 0.042-inch outer diameter (e.g., Marksman 0.027-inch ID or smaller) allows accurate transduction of pulse pressure. Further validation of these benchtop findings is necessary before application in a clinical setting.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…