Bmc Cardiovasc Disor · Jun 2017
Efficacy of a seal-wing paclitaxel-eluting balloon catheters in the treatment of bare metal stent restenosis.
- Leos Pleva, Pavel Kukla, Jana Zapletalova, and Ota Hlinomaz.
- Department of Cardiovascular Diseases, University Hospital Ostrava, tr. 17. listopadu 1790, 708 52, Ostrava, Czech Republic. leos.pleva@volny.cz.
- Bmc Cardiovasc Disor. 2017 Jun 26; 17 (1): 168.
BackgroundOur study aimed to compare the efficacy of seal-wing paclitaxel-eluting balloon catheters (PEB) with iopromide-coated PEB and everolimus-eluting stents (EES) for treating bare metal stent restenosis (BMS-ISR).MethodsWe enrolled 64 patients with 69 BMS-ISR. The control group comprised patients from the iopromide-PEB and EES arms of a previous TIS study. The primary end-point was 12-month in-segment late lumen loss (LLL). Secondary end-points included incidence of binary in-stent restenosis and 12-month major adverse cardiac events (MACE).ResultsCompared to iopromide-coated PEB, seal-wing PEB was associated with significantly higher 12-month LLL (0.30 vs. 0.02 mm; p < 0.0001), repeated binary restenosis (28.12% vs. 8.7%; p = 0.012), 12-month MACE (26.98% vs. 10.29%; p = 0.003), and target vessel revascularization (TVR; 20.63% vs. 7.35%; p = 0.009). Compared to EES, no significant differences were found in the 12-month LLL (0.30 vs. 0.19 mm; p = 1.000), repeated binary restenosis (28.12% vs. 19.12%; p = 0.666), 12-month MACE (26.98% vs. 19.12%; p = 0.102) or TVR (20.63% vs. 16.18%; p = 0.360).ConclusionBMS-ISR treatment using seal-wing PEB led to significantly higher 12-month LLL, repeated binary restenosis, MACE, and TVR compared to iopromide-coated PEB. However, no significant differences were found in comparison with EES.Trial RegistrationClinicalTrials.gov; NCT01735825.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.